10 the window menu, 11 the help menu, 5 next – Teledyne LeCroy Inspector - Users Manual User Manual
Page 59

CATC
CATC Inspector User’s Manual
Version 2.31
55
4.9.4.6 Find Data String
Selecting the Data String button brings up the following dialog box, to allow selection of a
specific data pattern within the DATA fields of the traffic file:
Up to 10 bytes of data (hexadecimal notation, MSB of each byte on the left) can be specified.
Selecting the “OK” button will then launch the search for a packet with the selected data string,
using the search direction, origin, and scope previously specified.
An example: to search for the standard device request “Get Device Descriptor”, specify the data
string ‘
80060001
’
.
Note: Data string searches are performed on a strict bit-by-bit basis; thus, if the specified bit
string appears anywhere within a data field (whether or not its position-based
hexadecimal representation is identical to that entered) it will produce a match.
4.9.5 Next
Selecting the “Next” menu item (or the associated toolbar icon) will repeat the previous search;
that is, it will initiate another search using the previously selected parameters (recall that
“start/end of file” origins are automatically converted to “last match”). In keeping with Windows
tradition, function key F3 also invokes this function.
4.10 The Window Menu
The Window menu is a standard Windows function that allows the open windows to be viewed
and arranged in different ways.
4.11 The Help Menu
The Help menu is a standard Windows function that supplies additional information on the
various functions of the CATC Inspector program when it is in use.