10 the window menu, 11 the help menu, 5 next – Teledyne LeCroy Inspector - Users Manual User Manual
Page 59
![background image](/manuals/353622/59/background.png)
CATC
CATC Inspector User’s Manual
Version 2.31
55
4.9.4.6 Find Data String
Selecting the Data String button brings up the following dialog box, to allow selection of a
specific data pattern within the DATA fields of the traffic file:
Up to 10 bytes of data (hexadecimal notation, MSB of each byte on the left) can be specified.
Selecting the “OK” button will then launch the search for a packet with the selected data string,
using the search direction, origin, and scope previously specified.
An example: to search for the standard device request “Get Device Descriptor”, specify the data
string ‘
80060001
’
.
Note: Data string searches are performed on a strict bit-by-bit basis; thus, if the specified bit
string appears anywhere within a data field (whether or not its position-based
hexadecimal representation is identical to that entered) it will produce a match.
4.9.5 Next
Selecting the “Next” menu item (or the associated toolbar icon) will repeat the previous search;
that is, it will initiate another search using the previously selected parameters (recall that
“start/end of file” origins are automatically converted to “last match”). In keeping with Windows
tradition, function key F3 also invokes this function.
4.10 The Window Menu
The Window menu is a standard Windows function that allows the open windows to be viewed
and arranged in different ways.
4.11 The Help Menu
The Help menu is a standard Windows function that supplies additional information on the
various functions of the CATC Inspector program when it is in use.