TABLE 15

UP/DOWN FREQUENCY CONTROL PROGRAMMING

Function No.

Code/Range

1.00: Run/Stop-Forward/Reverse Control 0001: External Contacts
2.00:
Frequency Control

0005: Up/Down Using MFITs

7.04: Multi-Function Input Terminal 5 0010:

N.O. Start*

7.05: Multi-Function Input Terminal 6 0003:

Up Frequency Command*

7.06: Multi-Function Input Terminal 7

0004: Down Frequency Command.

7.14: Up/Down Frequency Control Mode 0000: Free-Running 0001: Incremental
7.15:
Increment of Up/Down Frequency** 0.01 – 30.00 Hz: Set to Desired Frequency

*Factory setting.
**Use with Function No. 7.14 code "0001" only.


FIGURE 23

UP/DOWN FREQUENCY CONTROL

WITH 2-WIRE START/STOP CONNECTIONS

*Use a jumper, between Terminals "5" and "8", if a Start/Stop Switch
or Contact is not required.



A3. ACCEL/DECEL 2

The drive provides a secondary Accel/Decel Time setting, which can be remotely selected with a normally
open switch or contact connected to a Multi-Function Input Terminal. See Table 16, for drive programming.
See Figure 24, on page 36, for connections.

Connect the Accel/Decel 2 Switch or Contact to any Multi-Function Input Terminal "1" – "7". Terminal "6" has
been arbitrarily chosen for Accel/Decel 2. Connect the common of the switch or contact to any available
common terminal ("8", "12", "14", "16", "18", "20", "22").

Operation: When the Accel/Decel 2 Switch or Contact is closed, the Accel/Decel 2 setting is selected. When
the Accel/Decel 2 Switch or Contact opened, the drive reverts to the Accel/Decel settings in Function Nos.
3.03 and 3.04. Accel/Decel 2 overrides the Accel and Decel settings in Function Nos. 3.03 and 3.04.


TABLE 16

ACCEL/DECEL "2" PROGRAMMING

Function No.

Code/Range

7.05: Multi-Function Input Terminal 6 0005:

Accel/Decel 2

7.16: Accel/Decel 2 Time 0.3

180.0:

Set to Desired Time*

*Factory set to 1.5 seconds.