KB Electronics KBMK-24DF User Manual
Page 15
15
FIGURE 11
TYPICAL HI-POT TEST SETUP
TEST
RESET
RETURN
H. V.
0mA
10mA
VOLTAGE
MAX
ZERO
LEAKAGE
9 DRIVE OPERATION
Before operating the drive, read Section 9.2, for instructions on the Digital Keypad Operation. See Figure 2, on
page 8, for the keypad layout.
The 4-digit display can indicate various functions of the drive: Set Frequency, Motor RPM, Output Current and
Voltage, Custom Units, Function Numbers, Function Codes or Values, and Fault Codes. See Section 9.4, on
page 20.
See Section 9.3, on pages 16 – 19, for information on programming the drive. If an error message appears
while programming the drive, see Section 9.5, on page 21.
9.1 START-UP
PROCEDURE: After the drive has been properly setup and all connections completed, the
start-up procedure can begin. If the AC power has been properly brought to the drive, the LEDs on the
front cover will indicate the drive's status, as described in Section 11, on page 29. See Section 9.4, on
page 20, for the Digital Readout Codes.
To start the drive, press the RUN Key. The motor will begin to accelerate to the Set Frequency. The
factory set frequency is 05.00 Hz.
9.2 KEYPAD
DESCRIPTION:
The Keypad has eight (8) keys, which are used to program drive functions, as
described in Table 6. The eight (8) LEDs provide indication of the drive’s operational status, as
described in Section 11, on page 24. A Built-In Speed Potentiometer is also provided to set the Drive
Frequency (Function No. 2.00 set to "0001"). See Figure 2, on page 8.
Note: To avoid damage, never operate the keypad with a screwdriver or other sharp-ended tool.