beautypg.com

KB Electronics KBMK-24DF User Manual

Page 32

background image

32

FIGURE 21

IODA TERMINAL BLOCK TB1 LAYOUT

Common Terminals "8", "12", "14", "16", "18, "20", "22" are all internally connected and are shown shaded.

TABLE 11

IODA FUNCTIONS, FEATURES, AND TERMINAL ASSIGNMENT

Terminal Assignment

Multi-Function
Input Terminal Codes

MFIT

1

(Digital Inputs)

Power

Supply

2

Multi-

Function

Outputs

2

Analog

Outputs

2

Analog
Inputs

2

Relay

Outputs

3

0000: Preset Frequency Operation

1

0001: Preset Frequency Operation

1

0002: Preset Frequency Operation

1

0003: Up Frequency Command
(See Function No.7.14)
0004: Down Frequency Command
(See Function No. 7.14)
0005: Accel/Decel 2
(See Function No. 7.16)
0006: Forward/Stop Command
0007: Reverse/Stop Command
0008: External Fault (N.O. Contact)
0009: Reset
0010: N.O. Start
(2-Wire or 3-Wire Start/Stop)
0011: N.C. Stop
(3-Wire Start/Stop)
0012: External Fault (N.C. ontact)

1 – 7

8

Common

9

+5 Volts

10

-5 Volts


11

Open

Collector 1

12

Common

13

Open

Collector 2

14

Common

15

Analog Out 1

16

Common

17

Analog Out 2

18

Common

19

Analog In 1

20

Common

21

Analog In 2

22

Common

23

Relay 1 N.O.

24

Relay 1

Common

25

Relay 1 N.C.

26

Relay 2 N.O.

27

Relay 2

Common

28

Relay 2 N.C.

Notes: 1. Multi-Function Input Terminals "1" – "7" can be programmed for: 7 Preset Frequencies*, Up or Down
Frequency Command, Accel/Decel 2, Forward/Stop, Reverse/Stop, External Fault, Reset, and 2-Wire/3-Wire
Start/Stop. 2. Common Terminals 8, 12, 14, 16, 18, 20, and 22 are all internally wired together and can be used
with any of the Multi-Function Input Terminals "1" – "7". 3. Relay 1 Common (Terminal 24) is the contact common
only for Relay 1. Relay 2 Common (Terminal 27) is the contact common only for Relay 2.

*The 7 Preset Frequencies are obtained using a combination of Terminals 1, 2, 1+2, 3, 1+3, 2+3, 1+2+3.

TABLE 12

MULTI-FUNCTION INPUT TERMINAL, FUNCTION NO., AND CODE ASSIGNMENT

MFIT:

1 2 3 4 5 6 7

Function No.:

7.00 7.01 7.02 7.03 7.04 7.05 7.06

Factory Code Setting:

0000 0001 0002 0009 0010 0003 0004

Code Description:

Preset

Frequency

Operation

Preset

Frequency

Operation

Preset

Frequency

Operation

Reset

2-Wire

N.O.

Start/Stop

Up

Frequency

Command

Down

Frequency

Command

Each Multi-Function Input Terminal is controlled by a specific Function No.

Although factory set to a specific code, they can also be reprogrammed to any Function Code "0000" – "0012"

listed in Table 11, above. Also see Function Group 7, on page 26.

This manual is related to the following products: