KB Electronics KBMK-24DF User Manual
Page 28
28
FUNCTION GROUP 10 – Communication Mode (DIAC Required)
Function
No. Description
Range/Code
Factory
Setting
10.00 *
Assigned Communication Station
Number
1 – 247
30
10.01 Communications
Watchdog
Timer
0000: Disabled 0001: Enabled
0000
10.02 Watchdog
Timeout
(Seconds)
0.50 – 2.00
0.50
0 0: Stop 1: Run
1 0: Forward 1: Reverse
2 0: N/A 1: Fault Reset
3
0: JOG-LCL/REM Command Off
1: JOG-LCL/REM Command On
4 0: N/A 1: Preset Frequency 1
5 0: N/A 1: Preset Frequency 2
6 0: N/A 1: Preset Frequency 3
7 0: N/A 1: Preset Frequency 4
8 0: N/A 1: Preset Frequency 5
9 0: N/A 1: Preset Frequency 6
10 0: N/A 1: Preset Frequency 7
10.03 Operational
Command
11–15 Reserved
──
0 0: Stop 1: Run
1 0: Forward 1: Reverse
2 0: Normal 1: Fault
3
0: JOG-LCL/REM Command Off
1: JOG-LCL/REM Command On
4 0: N/A 1: Preset Frequency 1
5 0: N/A 1: Preset Frequency 2
6 0: N/A 1: Preset Frequency 3
7 0: N/A 1: Preset Frequency 4
8 0: N/A 1: Preset Frequency 5
9 0: N/A 1: Preset Frequency 6
10 0: N/A 1: Preset Frequency 7
11
0: Jog Momentary Mode
1: Jog Latching Mode
12
Reserved
13 0:
Local 1:Remote
10.04 Drive
Status
14, 15 Reserved
──
00
Normal Operation
01
Short Circuit Trip
02
Current Limit
03
Current Limit Trip
04
Undervoltage Trip
05
Recovered Undervoltage Trip
06
Overvoltage Trip
07
Recovered Overvoltage Trip
08
Stop Mode
09
Flash Error
10
External Fault Trip (IODA)
11
IODA Error
12
Phase Loss Trip
10.05 Drive Status Description
13
Current Source Trip (IODA)
──
10.06 ** Communications Error Count
──
──
10.07 ** Motor Voltage
──
──
10.08 ** Motor Current
──
──
10.09 ** Bus Voltage
──
──
10.10 ** Motor Frequency
──
──
*Functions which can only be changed while the drive is in the Stop Mode.
**Read only.