KB Electronics KBDA-42 User Manual
Models kbda-24p & kbda-42 supplement, Table 3a electrical ratings
MODELS KBDA-24P & KBDA-42 SUPPLEMENT
IMPORTANT: The KBDA Series manual must be read and understood before attempting
to operate the drive. For further assistance, contact our sales Department at
954-346-4900 or Toll Free at 800-221-6570 (outside Florida).
DESCRIPTION: Models KBDA-24P and KBDA-42 have been added to the KBDA Series
of drives. These models are designed to accept 3-phase AC line input only. Table 3A
shows the Electrical Ratings. Figure 11A shows the AC Line input, Motor, and Ground
connections to Terminal Block TB1. The General Performance Specifications have not
changed (see the manual for specifications). Both models contain AC Line Phase Loss
Detection.
WARNING! HIGH VOLTAGE!
DISCONNECT MAIN POWER BEFORE MAKING CONNECTIONS TO THE DRIVE
TABLE 3A
ELECTRICAL RATINGS
AC Line Input
Output
Model
Part No.
(Gray / White
1
)
Volts AC
(50/60 Hz)
Phase
(Ф)
Maximum
Current
(Amps AC)
Fuse or
Circuit
Breaker
Rating
(Amps)
Voltage
Range
(Volts AC)
Maximum
Continuous
Load Current
(RMS Amps/Phase)
Maximum
Horsepower
(HP (kW))
KBDA-24P 9766 / 9767
208/230
3
4.7
10
0 – 208/230
3.6
1 (0.75)
KBDA-42
2
9763 / 9764
400/460
3
2.6
5
0 – 400/460
2.0
1 (0.75)
Notes: 1. White FDA approved finish. 2. Model KBDA-42 is rated 0 – 400 Volts AC for 50
Hz motor operation and 0 – 460 Volts AC for 60 Hz motor operation.
FIGURE 11A
AC LINE INPUT, MOTOR, AND GROUND CONNECTIONS
KB
Electronics,
Inc.
12095 NW 39th Street, Coral Springs, FL 33065-2516 ● (954) 346-4900 ● FAX (954) 346-3377
Outside Florida Call Toll Free (800) 221-6570 ● [email protected]
www.kbelectronics.com
(A42040) – Rev. A00 – 6/9/2009
MODELS KBDA-24P & KBDA-42 SUPPLEMENT
IMPORTANT: The KBDA Series manual must be read and understood before attempting
to operate the drive. For further assistance, contact our sales Department at
954-346-4900 or Toll Free at 800-221-6570 (outside Florida).
DESCRIPTION: Models KBDA-24P and KBDA-42 have been added to the KBDA Series
of drives. These models are designed to accept 3-phase AC line input only. Table 3A
shows the Electrical Ratings. Figure 11A shows the AC Line input, Motor, and Ground
connections to Terminal Block TB1. The General Performance Specifications have not
changed (see the manual for specifications). Both models contain AC Line Phase Loss
Detection.
WARNING! HIGH VOLTAGE!
DISCONNECT MAIN POWER BEFORE MAKING CONNECTIONS TO THE DRIVE
TABLE 3A
ELECTRICAL RATINGS
AC Line Input
Output
Model
Part No.
(Gray / White
1
)
Volts AC
(50/60 Hz)
Phase
(Ф)
Maximum
Current
(Amps AC)
Fuse or
Circuit
Breaker
Rating
(Amps)
Voltage
Range
(Volts AC)
Maximum
Continuous
Load Current
(RMS Amps/Phase)
Maximum
Horsepower
(HP (kW))
KBDA-24P
9766 / 9767
208/230
3
4.7
10
0 – 208/230
3.6
1 (0.75)
KBDA-42
2
9763 / 9764
400/460
3
2.6
5
0 – 400/460
2.0
1 (0.75)
Notes: 1. White FDA approved finish. 2. Model KBDA-42 is rated 0 – 400 Volts AC for 50
Hz motor operation and 0 – 460 Volts AC for 60 Hz motor operation.
FIGURE 11A
AC LINE INPUT, MOTOR, AND GROUND CONNECTIONS
KB
Electronics,
Inc.
12095 NW 39th Street, Coral Springs, FL 33065-2516 ● (954) 346-4900 ● FAX (954) 346-3377
Outside Florida Call Toll Free (800) 221-6570 ● [email protected]
www.kbelectronics.com