IAI America ACON-CY User Manual
Page 51

39
4. Position T
able Settings
(12) Standstill
mode
x This field defines the power-saving mode to be applied while the actuator is standing by
after completing the positioning to the target position set in the “Position” field under the
applicable position number.
0: Power-saving mode is disabled. * The factory setting is “0” [Disable].
1: Automatic servo-off mode. The delay time is defined by Parameter No. 36.
2: Automatic servo-off mode. The delay time is defined by Parameter No. 37.
3: Automatic servo-off mode. The delay time is defined by Parameter No. 38.
The servo automatically turns off after elapse of a specified time following the completion of positioning.
(Since no holding current is required, power consumption decreases.)
When the PLC issues the next move command, the servo will turn on again and the actuator will start
moving.
Automatic servo-off mode
Move command
Servo status
Actuator movement
Servo on
Automatic servo-off mode
(The green LED blinks.)
Delay time after completion of positioning until
the servo turns off (sec)
This delay time is set by a parameter.
Target position