6. Inspection/Maintenance
20. If you have performed an absolute reset of both the rotational axis and vertical axis or allowed the home
preset value of arm 1 or arm 2 to be updated automatically by mistake, closing the absolute reset window
will open the following dialog box. Click
No on this dialog box.
y Click
Yes only if any of the mechanical fastenings has been released, such as when any arm or belt has
been replaced.
y Click
No if you have only replaced a cable or cables.
y After you have completed all of the above steps, be sure to perform a “software reset.”
21. Perform a software reset.
Click
Control (C) from the menu bar and then select Software Reset (R) to perform a software reset.
(Refer to 6.3.5.)