9. Maintenance and Inspection

Motor flange

6) Remove the motor.

䈄 Remove the affixing bolts (M3 × 15, 2 pcs./M3 × 18, 2 pcs.) using an Allen wrench of 2.5 mm across

flats.

‡'HFRXSOHGPRWRU

‡3XOORXWWKHPRWRUE\KDQG

‡5HPRYHWKHPRWRUIODQJH

Remove the affixing bolts (M3 × 8, 4 pcs.) using an
Allen wrench of 2.5 mm across flats.