9. Maintenance and Inspection
Motor flange
6) Remove the motor.
䈄 Remove the affixing bolts (M3 × 15, 2 pcs./M3 × 18, 2 pcs.) using an Allen wrench of 2.5 mm across
flats.
'HFRXSOHGPRWRU
3XOORXWWKHPRWRUE\KDQG
5HPRYHWKHPRWRUIODQJH
Remove the affixing bolts (M3 × 8, 4 pcs.) using an
Allen wrench of 2.5 mm across flats.