SecurityMan LCDDVR4 User Manual
Page 37
31
BUZZER DURATION
Buzzer Duration refers to the built-in buzzer sound when the alarm triggered.
It can be set to OFF (system default), 5 seconds, 10 seconds, 15 seconds, 20
seconds, 25 seconds, 30 seconds, or CON’T (Continuous). As its name imply,
Buzzer Duration is use to configure the length of time the buzzer will sound
when an event occur.
Buzzer Duration is works independently from Event REC
Duration time setting. To setup
Buzzer Duration browse to buzzer duration
using the front panel, remote control or mouse to hover over buzzer duration.
Change the value by pressing on the
CH3← (decrease value), CH4→/[Select/
Enter](increase value) buttons on the front panel, RC or mouse click on the
◄ ► red arrows. Press
Menu/ESC or right click mouse anytime to exit out of
Alarm setup menu.
EVENT REC DURATION
Event REC Duration implies to the time of recording periods after an event
occur, motion/sensor record time holding; when an event occur the DVR start to
record and end the recording when the time expire.
Event REC Duration can be
set from 05 seconds, 10 seconds (system default), 15 seconds, 20 seconds, 25
seconds or 30 seconds. To change the value press the
CH3← (decrease value),
CH4→/[Select/Enter](increase value) buttons on the front panel, RC or mouse
click on the ◄ ► red arrows. Press
Menu/ESC or right click mouse anytime to
exit out of
Alarm setup menu.
SENSOR