Data No.70 Full Scale Current [A]
Data No.71 High Current Limit [A]
Data No.72 Low Current Limit [A]
Data No.73 Fastening Current Limit [A]
Setting range: 0 ~ Due to unit type
Set the values below according to the unit type that will be used.
Used as a redundant check of the fastening process. Please contact FEC Inc. for assistance.
Unit Type
Tool Type
Full Scale Cur-
rent [A]
High Current
Limit [A]
Low Current Lim-
it [A]
Controlled Cur-
rent [A]
SAN3-24M
NFT -
□□□RM1
12.0
12.0
0.0
12.0
NFT -
□□□RM2
24.0
24.0
0.0
24.0
SAN3-40M
NFT -
□□□RM3
40.0
40.0
0.0
40.0
SAN3-120TM
NFT -
□□□RM4
80.0
80.0
0.0
80.0
SAN3-120WM
NFT -
□□□RM5
120.0
120.0
0.0
120.0
Data No.1A 1 Pulse Reverse Torque [Nm, Kgm...]
Setting range: 0 ~ [10: Calibration torque] × 1.1
Maximum torque value that will be applied to the fastener in reverse when the 1 Pulse reverse func-
tion is enabled.
1 Pulse reverse is used to disengage the Socket from the Fastener when a locking condition can oc-
cur.
Data No.55 1 Pulse Reverse Speed [rpm]
Setting range
: 1 ~ Tool’s maximum rpm
Speed value that will be applied to the fastener in reverse when the 1 Pulse reverse function is ena-
bled.
Data No.64 1 Pulse Reverse Time [sec]
Setting range: 0 ~ 99.9
Time value that will be applied to the fastener in reverse when the 1 Pulse reverse function is ena-
bled. The Reverse operation will be maintained for as long as this time is set for.