FEC AFC1500 User Manual
Page 123

AFC1500 Operations Manual
Chapter 7: System Operations (Rev. 6.1: 1/13)
Page 7-9
7.2.5 Parameter Data List
Item
Parameter No.
PARM
Data No.
D-NO
DATA
Unit
System
00
00
Torque Unit [0:Nm]
00
01
NR Version / Parameter Copy
<*Cannot be changed>
00
02
Amplifier Version <*Cannot be changed>
00
03
Stand Alone or Multi Config. See 7.3.7
00
04
External Gear Ratio
00
07
Angle Decimal Point
Tool
Data
<*Cannot be
changed>
00
10
Connected Tool No.
00
11
Tool CAL Torque
Kgm
00
12
Tool CAL Voltage
V
00
13
Tool Zero Torque Voltage
V
00
14~1A In-house Management Data
00
1B/1C
Tool Fastening Count (First 4 digits/ last 4 digits)
Tool type
00
20
Tool No.
Time
(only avail.)
(w/SAN3-DPx)
00
30
Date: Year “2009” 2009
00
31
Date: Month /
Day “705” 07 / 05
00
32
Time: Hours / Minutes “1510” 15:10
00
33
Time: Seconds “43” :43
○ Available × Cannot be changed
Item
[Unit]
Parameter No.
PARM
Data No.
D-NO
DATA
Torque
Method
Angle
Method
Offset
Check
Fastening
01~16
00
Fastening Mode (Step + Method)
XXX0
XXX1
XXXX
01~16
05
Fastening Option 1
0000
0000
0200
01~16
06
Fastening Option 2
○
○
○
Torque
[Nm]
01~16
10
Calibration torque (CAL value)
○
○
○
01~16
11
Peak Low Torque Limit
○
○
01~16
12
Peak High Torque Limit
○
○
01~16
13
Standard Torque
○
01~16
14
Speed Change Torque
○
○
01~16
15
1ST Torque
○
○
01~16
16
Snug Torque
○
○
01~16
17
Threshold Torque
(1
st
torque rate start torque)
○
○
01~16
18
Crossover Torque
(3
rd
torque rate start torque)
○
○
01~16
19
Torque Inhibit Limit
○
○
○
01~16
1A
Offset Torque Limit
○
1 Pulse Reverse Torque Limit
○
○
01~16
1B
Breakaway Torque Limit
○
○
01~16
1C
Final Low Torque Limit
○
○
01~16
1D
Final High Torque Limit
○
○
01~16
1E
2ND Rate Start Torque
○
○
Angle
[deg]
01~16
20
Low Angle Limit
○
○
01~16
21
High Angle Limit
○
○
01~16
22
Standard Angle
○
01~16
23
1ST Angle
○
01~16
24
Crossover Angle
(3
rd
torque rate start angle)
○
01~16
25
Angle Correction
○
○
01~16
26
2
nd
Rate Start Angle (Not Used)
Ч
○