3 fastening results display mode – FEC AFC1500 User Manual
Page 120

Chapter 7: System Operations
Page 7-6
7.2.3 Fastening Results Display Mode.
In Fastening Results Display mode (when [D-NO] shows _0 ~
), data can be obtained by
pressing the [
] and [
] keys to scroll the [D-NO] until the desired DATA item is displayed.
The following information will be displayed in the [DATA] display section for the displayed
[D-NO]:
D-NO
DATA
Unit *
_0
Peak Torque Value (Judgment torque value)
Nm
_1
Final Angle Value
deg
_2
1ST Torque Rate Value
Nm/deg
_3
2ND Torque Rate Value
Nm/deg
_4
1ST Area Fastening Time
Sec
_5
Final Area Fastening Time
Sec
_6
Cycle Time
Sec
_7
Fastening Mode No.
_8
3RD Torque Rate Value
Nm/deg
_9
Not Used
0
Fastening Method No.
=1
Step
=2
Not Used
=3
Self Check ON: Checked OFF: Unchecked
=4
Reverse Flag ON: Reversed OFF: Not reversed
=5
Cause of Fastening stop 0: Reset / No data / After reverse
1: Abnormal 2: BYPASS signal 3: Stop signal
4: REJECT 5: ACCEPT (Normal)
=6
Torque Judgment tq H/L (Final) H/L (Peak)
=7
Angle Judgment An H/L (Angle)
=8
Torque Rate Judgment r H/L (1ST) H/L (2ND) H/L (3RD)
=9
Time Judgment ti H/L (1ST) H/L (FNL) /
r (left) = Low rundown rev
– r (right) = High rundown rev
0
1ST Torque Rate Area Increment Torque
Nm
1
2ND Torque Rate Area Increment Torque
Nm
2
Offset Torque
Nm
3
1ST Peak Torque
Nm
4
Final Torque Value
Nm
5
Angle at Peak Torque (Judgment Torque)
deg
6
Maximum Current Value
A
Not Used
Unit of measure for Torque can be Nm, Kgm, Kgcm, Ftlb or Inlb
FIG. 7-2-3 Fastening results display selection