9060-zirconia analyser – Teledyne 9060 - Zirconium oxide flue gas oxygen analyzer User Manual

Page 97

background image

9060-Zirconia

Analyser

Removed efficiency from setup 24, page 41
Changed setup 32, page 43
Changed appendix 1, page 55

2-4-98

April 1998 version

Changed the version # and date on pages 1 & 2
Output ranges on page 6
Transmitter output channels 1 and 2, page 40 and 41
Added very low oxygen range to channel 1 (10 to 10,000ppm) page 6

7-7-98

June 1998 version

A large part of the manual has been changed. Re print the whole manual.
Added menu items for the new 4-20 calibration method.
Set-up 6.1 changed for the new 4-20 calibration method.
Removed the fuel selection menu item.
Moved all set-up item numbers.
Added process alarm enable menu item.
Remove the fuel type selection.
Changed sensor to probe, cell to sensor in many places
Added a 1232 connection diagram on page 22

9-2-99

February 1999 version

Added the index
Did a comprehensive spell and grammar check.

16-5-99

May 1999 version

Added menu items 34, 35 and 36 covering the variable flue pressure entry.
All menu numbers changed from 33 up.
Removed the references to a separate thermocouple being necessary for o2-def, combustibles, CO2.
Added caution 5 at the front of the manual to warn of the use of the ext pressure input dangers.

4-6-99

May 1999 version

Small change to sections 3.20, 3.22 and 3.6

26-8-99

August 1999 version

Deleted all references to the 1233 probe, including the emf table appendix
Changed the temperature limits for 253MA probes to 1000

°C

Changed the probe lengths to include 1500 and 2000mm
Added variable combustibles output scaling
Added probe imp reading every 24 hours and manual instigation
Removed the flow guide tube references
Added the 47 ohm resistor for the var press input
Comment about checking the * is on an option to lock the selection
Auto selection of minutes/seconds print log

30-8-99

September 1999 version

Added FIL-3 disclaimer (page 9)

11-11-99

September 1999 version

Removed the O2 deficiency requiring a Flue thermocouple, in section 2.13

2-2-2000

February 2000 version

Updated the EPROM version number/date
Added 3.25 to the contents at the beginning of Chapter 3.
Completed the cal check comment 3.25
20/06/2000 P48 Step 34. “Flue Pressure Setup” Changed 4” WG to 1 kPa.; universal change kpa to kPa.

20/09/2000

August 2000 version

P43 Step 12. Changed “the underline polarity.” to “the same polarity.” Changed EPROM version to 2.76
dated August 2000,
26/09/00 p44, NOTE:. Changed “MAN AL” to “MAN CAL”, removed “If” from the start of the sentence.

2/10/2000

October 2000 version

Added MODBUS™ sections of 3.15 and 2.11 and Appendix 6
12/11/2000

October 2000 version

Changed “process temperature” to “process pressure”.
14/12/00

October 2000 version