beautypg.com

CNB MDC4050VR User Manual

Page 19

background image

19

Network Camera_ User manual

Add User

Attribute

You can assign different privileges to users for the access to

system resources.

Attributes are Audio, Bi-directional Audio and Pan/Tilt control.

For example, if you want a specified user to hear the audio

from the device, check Audio in the check box.

User List

You can list “user ids” and “ their attributes” here.

format : user id[A, BA, P] :

A – audio,

BA – bi-directional audio,

P – PTZ(Pan/Tilt/Zoom), attribute.

You can delete specific user by clicking on “DELETE” button.

Authentication

for Viewing

YES

SAVE

If you want to restrict viewing access to the product, check at the

box left to “Yes” and click on “Save”. Users need to input ID and

password to connect to the product in viewing mode.

If No, default

attribute

If you uncheck for the “Authentication for Viewing”, all users

can access the product with the same default attribute. Checked

attributes are enabled. Click “Save” to save the default attribute.

Time Setup

Current Time

It shows you the current time kept in the product.

Synchronize with

an Internet Time

Server

Synchronize the time kept in the product with the time kept in

time server on the internet at the right. When the time server is

out of the reach from the product, you can assign time server by

filling in “Specific Time Server” field.

Synchronize With

this Computer

Time

Synchronize the time kept in the product with the time in the PC.

Set Manually

Set the time manually. Fill in the fields with desired formats.

SAVE

Save the set-up parameters when parameters settings are

finished. You must click the “Save” once you finish the all

setting-up.

For maintaining more accurate time through continued time synchronization, set the time

synchronization with time server on the network or internet time server.

If ID and Password are lost, you can set the system again torough Factory Default as the

following:

When the power is applied to product, press the Factory Default button for more than 3 sec,

then all Setting Parameters will be returned to Factory Default.