Installation
Type 8025/8035 /
Seal
Nut
Washer
Screw
Cable clip
Fig. 10: Installation of a panel version of the 8025
→
Insert the 4 screws in the housing (from the front). Use the 4
supplied M4*25 screws if the cabinet door is too thick.
→
Insert the seal on the external threads of the 4 screws (rear of
the housing).
→
Put the assembly on the cutout, electronics turned to the inside
of the cabinet.
→
Put the 4 washers on the 4 screws.
→
Put a nut on each of the 4 screws and tighten the nuts to secure
the device to the cabinet.
→
Wire according to the instructions in chapter "8".
7.4.
installation of a wall-mounted
version of the 8025 flowmeter
note
risk of material damage if the cable glands are not tightly
screwed on the housing
• Before installing the wall-mounted housing on its support,
tighten the nuts of the entry item of the cables glands at a torque
of 1.5 Nm.
The flow transmitter in a wall-mounted version has 4 holes in the
bottom of the housing.
→
Remove the blanking strips covering the screws.
Blanking strips
ENTER
0....9
FLOW
Nut of the entry item
→
Loosen the 4 screws and open the cover to get access to the
holes [1].