English – Burkert Type 8035 User Manual
Page 15
15
Installation
Type 8025/8035 /
Table 1: Flow rate/ fluid velocity/ DN of S020 fitting and of S030 sensor-fitting diagram
S020 fitting
0.1
0.3 0.5
1
3 5
10
0.01
0.02
0.05
0.1
0.2
0.5
1
2
5
10
20
50
100
200
m
3
/h
0.2
0.5
1
2
5
10
20
50
100
200
500
1000
2000
3000
l/min
0.3 0.5 1
3 5
10
30
m/s
fps
US gpm
0.05
0.1
0.2
0.5
1
2
5
10
20
50
100
200
500
1000
DN 65
DN 50 (DN65)*
DN 40 (DN50)*
DN 32 (DN40)*
DN 25 (DN32)*
DN 20 (DN25)*
500
1000
2000
2000
5000
10000
5000
20000
5000
10000
20000
30000
50000
100000
DN 400
DN 350
DN 300
DN 250
DN 200
DN 150
DN 125
DN 100
DN 80
Flow rate
Flow velocity
Example
1)
S030 sensor-fitting
0.1
0.3 0.5 1
3 5
10
0.01
0.02
0.05
0.1
0.2
0.5
1
2
5
10
20
50
100
200
m
3
/h
l/min
0.3 0.5 1
3 5
10
30
m/s
fps
gpm
0.05
0.1
0.2
0.5
1
2
5
10
20
50
100
200
500
1000
DN65
DN50 (DN65)*
DN40 (DN50)*
DN32 (DN40)*
DN25 (DN32)*
DN20 (DN25)*
DN15 (DN15 / DN20)*
DN08
DN06
0.2
0.5
1
2
5
10
20
50
100
200
500
1000
2000
3000
Example
Flow rate
Flow velocity
Example:
• Specification: if the nominal flow
rate is 10 m
3
/h, the ideal flow
velocity is between 2 and 3 m/s.
• Solution: intersection between
flow rate and flow velocity in the
graph gives the appropriate pipe
diameter, DN40 (or DN50 for
the asterisked fittings).
1)
The device cannot be installed
onto the following DN20 fittings:
* For the fittings:
• with external threads acc. to
SMS 1145.
• with weld ends
acc. to SMS 3008,
BS 4825 / ASME BPE or
DIN 11850 Rg2.
• Clamp acc. to
SMS 3017 / ISO 2852,
BS 4825 / ASME BPE or
DIN 32676.
English