beautypg.com

Modulation analyzer, Timing measurement – Atec R-S-CMU200 User Manual

Page 40

background image

40 R&S

®

CMU200 Universal Radio Communication Tester

Version 09.00, October 2008

Power meter (frequency-selective) and power versus time

filter definition: passband

Filter Bandwidth

→ wide

2.0 MHz

Measurement bandwidth

Filter Bandwidth

→ narrow 1.3

MHz

Reference level for full dynamic range

GFSK signal

RF 1

0 dBm to +41 dBm

RF 2

–14 dBm to +33 dBm

RF 4 IN

–32 dBm to 0 dBm

Dynamic range

Filter Bandwidth

→ wide

>55 dB, rms

Level uncertainty

in temperature range +20 °C to +35 °C

RF 1, RF 2

from full scale setting down to –25 dB

<0.7 dB

RF 4 IN

from full scale setting down to –25 dB

<0.9 dB

Level uncertainty

in temperature range +5 °C to +45 °C

RF1, RF2

from full scale setting down to –25 dB

<1.0 dB

RF4IN

from full scale setting down to –25 dB

<1.1 dB

in manual mode

0.1 dB

Level resolution

in remote control mode

0.01 dB

Modulation analyzer

filter definition: passband

Filter Bandwidth

→ wide

2.0 MHz

Measurement bandwidth

Filter Bandwidth

→ narrow 1.3

MHz

Level range

GFSK signal

RF 1, RF 2, RF 4 IN

from full scale setting down to –25 dB

Total measurement range for frequency
offset and frequency deviation

–250 kHz to +250 kHz

Frequency offset uncertainty in
preamble

for deviation

≤ 160 kHz

≤2 kHz

for 100 kHz < deviation

≤ 200 kHz

11110000 pattern

≤2 %

Frequency deviation uncertainty in
payload

10101010 pattern

≤4 %

measured in burst related to frequency
offset value in preamble

10101010 pattern

max.

≤2 kHz

Frequency drift uncertainty

typ.

≤1 kHz

in manual mode

1 kHz

Frequency resolution

in remote control mode

1 Hz

Timing measurement

Range

±20

μs

Resolution

≤0.25 μs

Uncertainty

≤0.25 μs + resolution