16 R&S
®
CMU200 Universal Radio Communication Tester
Version 09.00, October 2008
Modulation analysis
Level range
peak envelope power (PEP)
RF 1
see footnote 4
–6 dBm to +53 dBm
RF 2
see footnote 4
–20 dBm to +39 dBm
RF 4 IN
–60 dBm to 0 dBm
Inherent phase error
GMSK <0.6°,
rms
<2°, peak
Inherent EVM
8PSK
≤1.0 %, rms
Frequency measurement uncertainty
≤10 Hz + drift of timebase,
see base unit specifications
Measurement bandwidth
selectable
500 kHz or 600 kHz
Burst power measurement
Reference level for full dynamic range
GMSK, RF Attenuation
→ Low Noise
RF 1
see footnote 4
+10 dBm to +53 dBm
RF 2
see footnote 4
–4 dBm to +39 dBm
RF 4 IN
–22 dBm to 0 dBm
Reference level for full dynamic range
8PSK, RF Attenuation
→ Low Noise
RF 1
see footnote 4
+6 dBm to +49 dBm
RF 2
see footnote 4
–8 dBm to +35 dBm
RF 4 IN
–26 dBm to –4 dBm
Filter
→ 500 kHz, rms
RF Attenuation
→ Low Noise
GMSK >72
dB
Dynamic range
8PSK >69
dB
result > –40 dB
<0.1 dB
Relative measurement uncertainty
–60 dB
≤ result ≤ –40 dB
<0.5 dB
Resolution
in active part of burst
0.1 dB
Measurement bandwidth
selectable
500 kHz or 600 kHz
Spectrum due to modulation
Reference level for full dynamic range
GMSK, RF Attenuation
→ Low Noise
RF 1
+10 dBm to +47 dBm
RF 2
–4 dBm to +33 dBm
RF 4 IN
–22 dBm to 0 dBm
Test method
relative measurement, averaging
Filter bandwidth
30 kHz resolution filter, 5 poles
Measurement
at an offset of ±
100/200/250/400/600/800/1000/1200/
1400/1600/1800 kHz
Dynamic range
with offset
≥ 1200 kHz
>74 dB