beautypg.com

Modulation analysis, Burst power measurement, Spectrum due to modulation – Atec R-S-CMU200 User Manual

Page 16

background image

16 R&S

®

CMU200 Universal Radio Communication Tester

Version 09.00, October 2008

Modulation analysis

Level range

peak envelope power (PEP)

RF 1

see footnote 4

–6 dBm to +53 dBm

RF 2

see footnote 4

–20 dBm to +39 dBm

RF 4 IN

–60 dBm to 0 dBm

Inherent phase error

GMSK <0.6°,

rms

<2°, peak

Inherent EVM

8PSK

≤1.0 %, rms

Frequency measurement uncertainty

≤10 Hz + drift of timebase,
see base unit specifications

Measurement bandwidth

selectable

500 kHz or 600 kHz

Burst power measurement

Reference level for full dynamic range

GMSK, RF Attenuation

→ Low Noise

RF 1

see footnote 4

+10 dBm to +53 dBm

RF 2

see footnote 4

–4 dBm to +39 dBm

RF 4 IN

–22 dBm to 0 dBm

Reference level for full dynamic range

8PSK, RF Attenuation

→ Low Noise

RF 1

see footnote 4

+6 dBm to +49 dBm

RF 2

see footnote 4

–8 dBm to +35 dBm

RF 4 IN

–26 dBm to –4 dBm

Filter

→ 500 kHz, rms

RF Attenuation

→ Low Noise

GMSK >72

dB

Dynamic range

8PSK >69

dB

result > –40 dB

<0.1 dB

Relative measurement uncertainty

–60 dB

≤ result ≤ –40 dB

<0.5 dB

Resolution

in active part of burst

0.1 dB

Measurement bandwidth

selectable

500 kHz or 600 kHz

Spectrum due to modulation

Reference level for full dynamic range

GMSK, RF Attenuation

→ Low Noise

RF 1

+10 dBm to +47 dBm

RF 2

–4 dBm to +33 dBm

RF 4 IN

–22 dBm to 0 dBm

Test method

relative measurement, averaging

Filter bandwidth

30 kHz resolution filter, 5 poles

Measurement

at an offset of ±

100/200/250/400/600/800/1000/1200/
1400/1600/1800 kHz

Dynamic range

with offset

≥ 1200 kHz

>74 dB