31
non-signaling mode
Frequency range
728 MHz to 768 MHz
869 MHz to 894 MHz
925 MHz to 960 MHz
1475.9 MHz to 1500.9 MHz
1805 MHz to 1880 MHz
1930 MHz to 1990 MHz
2110 MHz to 2170 MHz
2180 MHz to 2200 MHz
2620 MHz to 2690 MHz
signaling mode
band 1
2110 MHz to 2170 MHz
band 2
1930 MHz to 1990 MHz
band 3
1805 MHz to 1880 MHz
band 4
2110 MHz to 2155 MHz
band 5
869 MHz to 894 MHz
band 6
875 MHz to 885 MHz
band 7
2620 MHz to 2690 MHz
band 8
925 MHz to 960 MHz
band 9
1844.9 MHz to 1879.9 MHz
band 10
2110 MHz to 2170 MHz
band 11
1475.9 MHz to 1500.9 MHz
band 12
728 MHz to 746 MHz
band 13
746 MHz to 756 MHz
band 14
758 MHz to 768 MHz
Frequency range
band S
2180 MHz to 2200 MHz
Frequency offset
–100 kHz to +100 kHz
Frequency resolution
0.1
Hz
Frequency setting
by channel number or frequency
Output level range
depending on PAR
RF 1
PAR
≤ 10 dB
–120 dBm to –37 dBm
PAR
≤ 10 dB
–120 dBm to –20 dBm
RF 2
overranging
up to –15 dBm
PAR
≤ 10 dB
–100 dBm to 0 dBm
RF 3 OUT
overranging
up to +3 dBm