background image

Version 09.00, October 2008

R&S

®

CMU200 Universal Radio Communication Tester

29

Modulation analyzer

Level range

modulated signal

f < 2200 MHz

–40 dBm to +44 dBm

RF 1

f

≥ 2200 MHz

–34 dBm to +44 dBm

f < 2200 MHz

–54 dBm to +30 dBm

RF 2

f

≥ 2200 MHz

–48 dBm to +30 dBm

f < 2200 MHz

–80 dBm to –9 dBm

RF 4 IN

f

≥ 2200 MHz

–74 dBm to –9 dBm

Waveform quality (

ρ) uncertainty

for

ρ 0.9 to 1

<0.003

Frequency measurement range

–3 kHz to +3 kHz

Frequency measurement uncertainty

<10 Hz + drift of timebase,
see base unit specifications

Relative measurement uncertainty

result > –33 dB

<0.1 dB

Measurements

Modulation

overview
EVM versus time, graphical
ME versus time, graphical
PE versus time, graphical
I/Q analyzer

Power

standby/access-probe

power

open loop time response
narrowband power

Spectrum

adjacent channel power

Code domain power

code domain power
code domain error power
channel power

Receiver

in signaling mode

FTAP/RTAP, FETAP/RETAP