Rf analyzer, Influence on rf interface, Power meter (frequency-selective) – Atec R-S-CMU200 User Manual
Page 15

Version 09.00, October 2008
R&S
®
CMU200 Universal Radio Communication Tester
15
Output level range
8PSK
RF 1
without R&S
®
CMU-U99
with R&S
®
CMU-U99
–115 dBm to –76 dBm
–103 dBm to –64 dBm
RF 2
–103 dBm to –64 dBm
Output level range
GMSK overrange mode
RF 1
without R&S
®
CMU-U99
with R&S
®
CMU-U99
–110 dBm to –28 dBm
–90 dBm to –14 dBm
RF 2
–90 dBm to –14 dBm
RF 3 OUT
–70 dBm to +9 dBm
Output level range
8PSK overrange mode
RF 1
without R&S
®
CMU-U99
with R&S
®
CMU-U99
–110 dBm to –32 dBm
–90 dBm to –18 dBm
RF 2
–90 dBm to –18 dBm
RF 3 OUT
–70 dBm to +5 dBm
Output level resolution
1
dB
Influence on RF interface
Reduced input level range
if R&S
®
CMU-B96 is installed
RF 1
continuous input power
max. 2 W
RF level uncertainty
Use of the R&S
®
CMU-B96 in overrange
mode may influence all RF signal levels
and their quality.
RF analyzer
GSM400 band
450 MHz to 458 MHz
478 MHz to 486 MHz
GSM850 band
824 MHz to 849 MHz
GSM900 band
876 MHz to 915 MHz
GSM1800 band
1710 MHz to 1785 MHz
Frequency range
GSM1900 band
1850 MHz to 1910 MHz
Power meter (frequency-selective)
Level range
continuous power
3
–40 dBm to +47 dBm (50 W)
RF 1
peak envelope power
4
(PEP)
+53 dBm (200 W)
continuous power
–54 dBm to +33 dBm (2 W)
RF 2
peak envelope power
4
(PEP)
+39 dBm (8 W)
RF 4 IN
continuous power and PEP
–80 dBm to 0 dBm
in temperature range +20 °C to +35 °C
<0.5 dB
Level uncertainty
in temperature range +5 °C to +45 °C
<0.7 dB
in manual mode
0.1 dB
Level resolution
in remote control mode
0.01 dB
Measurement bandwidth
selectable
500 kHz or 600 kHz