beautypg.com

Rf analyzer (tx measurements), Influence on rf interface – Atec R-S-CMU200 User Manual

Page 34

background image

34 R&S

®

CMU200 Universal Radio Communication Tester

Version 09.00, October 2008

Influence on RF interface

Reduced input level range

if R&S

®

CMU-B96 is installed

RF 1

continuous input power

max. 2 W

RF level uncertainty

Use of the R&S

®

CMU-B96 in overrange

mode may influence all RF signal levels
and quality.

RF analyzer (TX measurements)

non-signaling mode

Frequency range

698 MHz to 716 MHz
777 MHz to 798 MHz
824 MHz to 849 MHz
880 MHz to 915 MHz
1427.9 MHz to 1452.9 MHz
1710 MHz to 1785 MHz
1850 MHz to 1910 MHz
1920 MHz to 1980 MHz
2000 MHz to 2020 MHz
2500 MHz to 2570 MHz

signaling mode

band 1

1920 MHz to 1980 MHz

band 2

1850 MHz to 1910 MHz

band 3

1710 MHz to 1785 MHz

band 4

1710 MHz to 1755 MHz

band 5

824 MHz to 849 MHz

band 6

830 MHz to 840 MHz

band 7

2500 MHz to 2570 MHz

band 8

880 MHz to 915 MHz

band 9

1749.9 MHz to 1784.9 MHz

band 10

1710 MHz to 1770 MHz

band 11

1427.9 MHz to 1452.9 MHz

band 12

698 MHz to 716 MHz

band 13

777 MHz to 787 MHz

band 14

788 MHz to 798 MHz

Frequency range

band S

2000 MHz to 2020 MHz

Frequency offset

–100 kHz to +100 kHz

Frequency resolution

1

Hz

Frequency setting

by channel number or frequency

Level setting

by autoranging or manual mode

Max. level setting range

RF 1

peak envelope power

4

(PEP)

–38 dBm to +53 dBm

RF 2

peak envelope power

4

(PEP)

–52 dBm to +39 dBm

RF 4 IN

peak envelope power (PEP)

–77 dBm to +0 dBm

Statistics

Statistic count

1 to 1000

Values

current, average, min./max.

Trigger

non-signaling mode

Trigger sources

free run, internal, external, IF power, slot,
frame, TPC, HSDPCCH, auto

Trigger input

15-pin D-Sub connector AUX 3, pin 8

external

Trigger slot delay

0 to 14 slots

Trigger delay offset

–10239 to + 10239 × 1/4 chip

Trigger output

15-pin D-Sub connector AUX 3, pins 2 to 5

frame, slot, TPC, HSDPCCH