General data

Operating temperature range

+5 °C to +45 °C,
in line with EN 60068-2-1 and -2

Storage temperature range

–25 °C to +60 °C,
in line with EN 60068-2-1 and -2

Humidity

+40 °C, non-condensing

80 % relative humidity,
in line with EN 60068-2-78

Electromagnetic compatibility

in line with EMC Directive 2004/108/EC,
applied standard: EN 61326
(immunity for industrial environment;
class B emissions)

Electrical safety

in line with IEC 61010-1: 2001 (ed. 2),
EN 61010-1: 2001 (ed. 2), UL 61010-1
(ed. 2), CAN C22.2 No. 61010-1-04

Mechanical resistance

non-operating mode

Vibration

sinusoidal

in line with EN 60068-2-6,
MIL-PRF-28800 F classes 3 and 4,
5 Hz to 150 Hz, max. 2 g at 55 Hz,
55 Hz to 150 Hz, 0.5 g const.

Vibration

random

in line with EN 60068-2-64
10 Hz to 300 Hz, acceleration 1.2 g rms

Shock

in line with MIL-STD-810D
40 g shock spectrum

Power supply

power factor correction,
in line with EN 61000-3-2

Input

100 V to 240 V ±10 % (AC), max. 500 VA,
50 Hz to 400 Hz –5 % to +10 %

base unit

approx. 130 W

Power consumption

with typical options

approx. 180 W

Display

21 cm TFT color display (8.4”)

Resolution

640 pixel × 480 pixel (VGA resolution)

Pixel failure rate

<2 × 10

–5

W × H × D

465.1 mm × 197.3 mm × 517.0 mm
(18.31 in × 7.77 in × 20.35 in)

Dimensions

for rackmounting

19” 1/1, 4 HU, 450

base unit

approx. 14 kg (approx. 31 lb)

Weight

with typical options