37
Spectrum emission mask
(SEM application)
Measurement filter
receiver filter in line with standard
3.84 MHz, RRC,
α = 0.22
Display
graphical and numeric values of current,
average and max. values
frequency offset
2.5 MHz to 3.5 MHz
30 kHz
3.5 MHz to 7.5 MHz
1 MHz
7.5 MHz to 8.5 MHz
1 MHz
Resolution bandwidth
8.5 MHz to 12.5 MHz
1 MHz
Measurement interval
≥1 timeslot (2560 chips)
≥1/2 timeslot (1280 chips)
≥1/4 timeslot (640 chips)
≥1/8 timeslot (320 chips)
Power meter (frequency-selective)
7
max. power, min. power
bandwidth approx. 7 MHz
off power
3.84 MHz, RRC,
α = 0.22
power versus slot
bandwidth approx. 7 MHz
Measurement applications
inner loop power
3.84 MHz, RRC,
α = 0.22
measurement width
0.25, 0.5, 1 slot
step width
1 slot to 30 slots
step count
1 to 100
Power versus slot
step delay
0 to 100
Level range
continuous power
3
–52 dBm to +47 dBm
RF 1
peak envelope power
4
(PEP)
–42 dBm to +53 dBm
continuous power
–66 dBm to +33 dBm
RF 2
peak envelope power
4
(PEP)
–56 dBm to +39 dBm
continuous power
8
–89 dBm to 0 dBm
RF 4 IN
peak envelope power (PEP)
–79 dBm to 0 dBm
Level uncertainty
in temperature range +20 °C to +35 °C
–10 dBm to +47 dBm, rms
f < 2200 MHz
<0.5 dB
f
≥ 2200 MHz
<0.7 dB
–44 dBm to –10 dBm, rms
f < 2200 MHz
<0.7 dB
RF 1
f
≥ 2200 MHz
<0.9 dB
–24 dBm to +33 dBm, rms
f < 2200 MHz
<0.5 dB
f
≥ 2200 MHz
<0.7 dB
–60 dBm to –24 dBm, rms
f < 2200 MHz
<0.7 dB
RF 2
f
≥ 2200 MHz
<0.9 dB
–24 dBm to 0 dBm, rms
f < 2200 MHz
<0.5 dB
f
≥ 2200 MHz
<0.7 dB
–85 dBm to –24 dBm, rms
f < 2200 MHz
<0.7 dB
–83 dBm to –24 dBm, rms
RF 4 IN
f
≥ 2200 MHz
<0.9 dB
7
The specified data is valid for RF Attenuation set to Low Noise.
8