Clock pod characteristics – Atec Agilent-16700 Series User Manual
Page 118
118
10463A ECL Clock Pod
Clock output type
10H116 differential unterminated; and differ-
ential with 330
Ω to –5.2V and 47 Ω series
Clock output rate
300 MHz maximum
Clock out delay
approximately 8 ns total in 14 steps (16720A
only); 11 ns maximum in 9 steps (16522A only)
Clock input type
ECL – 10H116 with 50 K
Ω to –5.2v
Clock input rate
dc to 300 MHz
Pattern input type
ECL – 10H116 with 50 K
Ω (no connect is
logic 0)
Clock-in to clock-out
approximately 30 ns
Pattern-in to recognition
approximately 15 ns + 1 clk period
Recommended lead set
Agilent 10474A
10H116
–5.2 V
VBB
50 k
Ω
CLKin
10H116
–5.2 V
330
Ω
47
Ω CLKout
Pattern Generation Modules Specifications
and Characteristics
Clock Pod Characteristics
10460A TTL Clock Pod
Clock output type
10H125 with 47
Ω series; true & inverted
Clock output rate
100 MHz maximum
Clock out delay
approximately 8 ns total in 14 steps (16720A
only); 11 ns maximum in 9 steps (16522A only)
Clock input type
TTL – 10H124
Clock input rate
dc to 100 MHz
Pattern input type
TTL – 10H124 (no connect is logic 1)
Clock-in to clock-out
approximately 30 ns
Pattern-in to recognition
approximately 15 ns + 1 clk period
Recommended lead set
Agilent 10474A
47
Ω
CLKout
10H125
WAIT
10H124
CLKin