beautypg.com

Atec Agilent-16700 Series User Manual

Page 104

background image

104

State/Timing Modules Specifications and
Characteristics

Agilent Technologies 16760A
Supplemental Specifications* and Characteristics (continued)

Synchronous state analysis

1.5 Gb/s mode

1.25 Gb/s mode

800 Mb/s mode

400 Mb/s mode

200 Mb/s mode

Maximum data rate

1.5 Gb/s

1.25 Gb/s

800 Mb/s

400 Mb/s

200 Mb/s

on each channel [3]

Minimum clock interval,

667 ps

800 ps

1.25 ns

2.5 ns

5 ns

active edge to active edge* [3]

Minimum state clock pulse

N/A

N/A

600 ps

1.5 ns

1.5 ns

width with clock polarity
rising or falling [3]

Clock periodicity

Clock must be periodic

Clock must be periodic

Periodic or aperiodic

Periodic or aperiodic

Periodic or aperiodic

Number of clocks

1

1

1

1

1

Clock polarity

Both edges

Both edges

Rising, falling, or both

Rising, falling, or both

Rising, falling, or both

Minimum data pulse width*

600 ps

750 ps

E5378A, E5379A, E5382A

1.5 ns

1.5 ns

probes: 750 ps

E5380A probe: 1.5 ns

Number of channels [1]

• With time tags

16 x (number of modules) -8

16 x (number of modules) -8

34 x (number of modules) -16

34 x (number of modules) -16

34 x (number of modules)

• Without time tags

16 x (number of modules)

16 x (number of modules)

34 x (number of modules) -1

34 x (number of modules)

34 x (number of modules)

Maximum channels on a

80 (5 modules)

80 (5 modules)

170 (5 modules)

153 (5 modules)

170 (5 modules)

single time base and trigger

Maximum memory depth

128M samples

128M samples

64M samples

32M samples

32M samples

Time tag resolution

4 ns [2]

4 ns [2]

4 ns [2]

4 ns [2]

4 ns

Maximum time count

17 seconds

17 seconds

17 seconds

17 seconds

17 seconds

between states

Trigger resources

3 Patterns on each pod

3 Patterns on each pod

4 Patterns on each pod

8 Patterns evaluated as

16 Patterns evaluated as

evaluated as =,

≠, >, <,

evaluated as =,

≠, >, <,

evaluated as =,

≠, >, <,

=,

≠, >, <, ≥, ≤

=,

≠, >, <, ≥, ≤

≥, ≤ on one pod; or

≥, ≤ on one pod; or

≥, ≤ on one pod; or

4 Ranges evaluated as

15 Ranges evaluated as

evaluated as =,

≠ across

evaluated as =,

≠ across

evaluated as =,

≠ across

in range, not in range

in range, not in range

multiple pods; or

multiple pods; or

multiple pods; or

2 Occurrence counters

Timers: 2 x (number of

1 range on each pod

1 range on each pod

2 ranges on each pod

4 Flags

modules) – 1

4 Flags

4 Flags

4 Flags

Arm in

2 Global counters

Arm in

Arm in

Arm in

1 Occurrence counter per

sequence level

4 Flags
Arm in

Trigger actions

Trigger and fill memory

Trigger and fill memory

Trigger and fill memory

Goto

Goto

Trigger and fill memory

Trigger and fill memory
Trigger and goto
Store/don’t store sample
Turn default storing on/off
Timer start/stop/pause/resume
Global counter increment/reset
Occurrence counter reset
Flag set/clear

* All specifications noted by an asterisk are the performance standards against which the product is tested.
[1] In 1.25 Gb/s and 1.5 Gb/s modes, only the even-numbered channels (0, 2, 4, etc.) are acquired.
[2] The resolution of the hardware used to assign time tags is 4 ns. Times of intermediate states are calculated.
[3] The choice of probe can limit system performance. Select a probe rated at the speed of the selected mode (or greater) to maintain system bandwidth.