beautypg.com

3 service power inserter (spi), Service power inserter (spi) – Alpha Technologies GMX-915 User Manual

Page 25

background image

25

017-932-B0-002, Rev. B

Fig. 3-, SPI Cover Removal

3.0

Installation, continued

3.3 Service Power Inserter (SPI)

Coaxial Cable Connection Procedure:

1. Ensure the SPI is unplugged from the power supply prior to removing cover.

2. Remove the two screws holding the cover to the SPI’s chassis.

3.

Remove the SPI cover, exposing the circuit board and seizure screw

assembly.

4. Insert the coaxial termination into the output port on the bottom of the SPI and tighten the

nut snug.

5. Tighten the seizure screw to 4 Nm (35 in-lbs).

Fig. 3-5, Coaxial Cable Insertion and Securing

To prevent arcing, insert the center conductor (stinger) of the coaxial termination completely inside

the seizure screw assembly (5). Tighten to 4 Nm (35 in-lbs).

Seizure Screw

Assembly

2

3

1

CAUTION!

4

5