beautypg.com

2 installing the optional ac indicator lamp, Installing the optional ac indicator lamp – Alpha Technologies GMX-915 User Manual

Page 23

background image

23

017-932-B0-002, Rev. B

The AC indicator (green lamp) is located on the outside of the enclosure. When the lamp

is on, it indicates AC power is available at the power supply output. This enables service

personnel to determine the status of the power supply without having to climb the pole.

Installation Procedure:

1. Remove rear-most knockout.

2. Feed ACI wires through hole.

3.

Slide locking nut over wires, and thread onto lamp body (see Fig. 3-1).

. Insert the crimped contacts on the short set of wires into the plastic connectors. The black

wire must always go into the black connector. Insert the remaining wire (may be white,

yellow, or blue in color) into the white connector (see Fig. 3-2).

Fig. 3-2, Wire/Connector Assembly

White Connector

Black Connector

Black Wire

Top View

White, Yellow, or Blue Wire

Verify contact

snaps over metal

retainer

Side View

3.0

Installation, continued

3.2 Installing the Optional AC Indicator Lamp

If the system configuration includes an ACI option, install per the following instructions.

NOTE:

To remove a wire from a plastic connector, depress the metal retainer with the Anderson insertion/extraction

tool, (Cat. Number 111038G2), and slide the wire out.

NOTE:

Verify that the contact is secure. Failure to properly position the contact will result in overheating,

and cable assembly failure.

CAUTION!

Fig. 3-1, AC Indicator

Enclosure Wall

Nylon Washer

To SPI

To V

out