Franklin Fueling Systems T5 Series Fuel Management System Operators Guide User Manual
Page 35

31
FMS
Line/Manifold Alarms
Displayed Alarm
Description
Recommended Actions
Reference Source
Dispenser Test
Failed
Line pressure must be above 12 psi
when the pump is on; and above 7.5 psi
while dispensing product.
Details of this test are summarized in LS500
Installation/User Guide (p/n 000-2145); see
this guide for troubleshooting.
Applicable Equipment
Guide*
Extended Hook
Signal
A hook signal has been active for more
than four hours.
Details of this test are summarized in LS500
Installation/User Guide (p/n 000-2145); see
this guide for troubleshooting.
Applicable Equipment
Guide*
Failed to Catch
Pressure
Line pressure has dropped below 12 psi
when the pump turned off.
Details of this test are summarized in LS500
Installation/User Guide (p/n 000-2145); see
this guide for troubleshooting.
Applicable Equipment
Guide*
Failed to
Pressure Up
Line pressure remained below 12 psi
when the pump turned on.
Details of this test are summarized in LS500
Installation/User Guide (p/n 000-2145); see
this guide for troubleshooting.
Applicable Equipment
Guide*
Gross Leak
Detected
The product line listed with the alarm
has failed a Gross Leak Test.
Details of this test are summarized in LS500
Installation/User Guide (p/n 000-2145); see
this guide for troubleshooting.
Applicable Equipment
Guide*
Monthly Leak
Test Failed
The product line listed with the alarm
has failed a Monthly Leak Test.
Details of this test are summarized in LS500
Installation/User Guide (p/n 000-2145); see
this guide for troubleshooting.
Applicable Equipment
Guide*
Annual Leak Test
Failed
The product line listed with the alarm
has failed a Precision Leak Test.
Details of this test are summarized in LS500
Installation/User Guide (p/n 000-2145); see
this guide for troubleshooting.
Applicable Equipment
Guide*
High Pump
Pressure
Line pressure has exceeded 50 psi.
Details of this test are summarized in LS500
Installation/User Guide (p/n 000-2145); see
this guide for troubleshooting.
Applicable Equipment
Guide*
Line is Not
Configured
The line listed with the alarm is not
configured in ‘Lines’ programming, or
the line is not properly mapped.
Programming details are summarized in
LS500 Installation/User Guide (p/n 000-
2145); see this guide for troubleshooting.
Lines Setup in
Programming Manual /
Applicable Equipment
Guide*
Line Disabled
The input channel for the 4-20mA
module connected to the line listed with
the alarm is not configured.
Verify programming of the 4-20mA Module
connected to the line listed with the alarm.
Module Setup in
Programming Manual /
Applicable Equipment
Guide*
Not Enabled
The product line listed with the alarm is
not enabled in the programming.
Programming details are summarized in
LS500 Installation/User Guide (p/n 000-
2145); see this guide for troubleshooting.
Applicable Equipment
Guide*
Not Learned
The product line listed with the alarm
has not been learned.
Programming details are summarized in
LS500 Installation/User Guide (p/n 000-
2145); see this guide for troubleshooting.
Applicable Equipment
Guide*
Pressure
Transducer
Failed
This alarm indicates a communication
error between the console and the
pressure transducer listed with the
alarm.
Verify the wiring and operation of the
transducer connected to the line listed with
the alarm.
Applicable Equipment
Guide*
Program Error
Detected
Firmware failed to function properly.
Upload the current firmware release.
Applicable Bulletins*
Pump Request
Ignored
The signal sent by the 4-20mA channel
did not receive confirmation to turn on
the pump listed with the alarm.
Verify 4-20mA and Relay Module
programming.
Module Setup in
Programming Manual /
Applicable Equipment
Guide*
Sudden Pressure
Loss
Line pressure has dropped from
above 12 psi to below 5 psi within five
seconds.
Details of this test are summarized in LS500
Installation/User Guide (p/n 000-2145); see
this guide for troubleshooting.
Applicable Equipment
Guide*
* Bulletins and the T5 Series Installation Guide (p/n 000-2150) and the T5 Series Programming Manual (000-2142) can be found on
Franklin Fueling’s web site - http://www.franklinfueling.com/service/. Select Technical Documentation / Fuel Management System