[Setup] / Fuel Management System / Products
Product #
Name
(Product 1)
Enter Product name
abc#
Type
(Unleaded
Regular)
Select type of fuel
Unleaded Regular, Plus,
Extra, Super, Diesel,
Kerosene, #2 Fuel Oil,
Ethanol, Special #
(20 Characters maximum)
[Setup] / Fuel Management System / Grades
Grade #
First Tank
(Tank 1)
Select tank number for first tank
Tank 1-6
Second tank
(none)
Select tank number for second tank
None, Tank 1-6
[Setup] / Fuel Management System / Reconciliation
Parameter
Parameter Value
Description
Value
Over Short Limit
Percent
(1.00)
Enter short limit percent
0-100
Over Short Limit
Volume
(130)
Enter short limit volume
#
Sales
yes
Include Sales
Yes / No
Deliveries
Yes
Include Deliveries
Yes / No
Tank Volume
Yes
Include tank volume
Yes / No
[Setup] / Fuel Management System / Autocalibration
Note: Must have Dispenser Interface connected for Autocalibration to work
Parameter
Parameter Value
Description
Value
Autostop Volume
Coverage
(100)
Enter volume percent at which the Autocalibration
will automatically stop.
0-100
Autostop Level
Coverage
(80)
Enter level percent at which the Autocalibration
will automatically stop.
0-100
Autostop Number of
Points Coverage
(100)
Enter number of points required at which the
Autocalibration will automatically stop.
0-100
Any of these parameters values can be set separately. If any of the values are met the autocalibration will stop.
• If you want a certain volume coverage, set volume to desired percentage and level and number of points to 100.
• If you want a certain level coverage, set level to desired percentage and set volume and number of points to 100.
• If you want so many points in the table, set number of points to desired number and set volume and level coverage to 100.
If you have accurate tank dimensions entered, you may not need Autocalibration. Refer to Appendix F for detailed
information on setting up and running Autocalibration.