SEM (TS-SEM) An abbreviation for the external Sensor Expansion Module (BriteBox) for the

connection of 8 leak detection sensors.

SENSOR SYNC A term used to describe a loss of synchronous data from the leak detection

sensor (usually because of a corroded, wet or broken cable wires, or a sensor failure).

SENTINEL MODE The after hours coarse leak test and theft monitoring mode (start and stop

time must be programmed).

SETUP The programming / configuration mode of the Tank Sentinel console. Setup should be

password protected for operation, security, and compliance reasons.

SLOPE The rate of change of product volume within a tank and can be either a positive or

negative (+/-) value. Slope is a value that is used in Tank Leak Testing to determine if a leak

exists or not. Slope is affected by leaks, product evaporation / vent loss, and by physical

interference and temperature fluctuations from dispensing or deliveries. Noise from other

tanks (cross-talk), leaky check valves in product-lines also disturb slope / leak tests results.

STD An abbreviation for a Standard leak detection sensor.

STP An abbreviation for Submerged Turbine Pump (the pump within the tank).

SUMP An underground containment area that is used to collect product spills (leak detection

sensors are usually mounted in these collection areas).

TGI (TS-TGI) An abbreviation for Tank Gauge Interface for / with line leak detectors.

TEMP The temperature of the product (from temperature sensors within the probe that are

submerged below the product level). Sensors above the product float level are excluded from

the probe temperature data set. Related subjects: GROSS, NET, PROBE and LEVEL.

TRANSIENT A term used to describe an instantaneous alarm or fault such as a memory error.

ULLAGE The remaining gross capacity of a tank, or the volume that can be added to the tank

without overfilling it (in gallons or liters). Ullage to full is 95% of the tanks total liquid volume

capacity. Also see CAPACITY.

UST An abbreviation for Underground Storage Tank.

WD TIMEOUT An abbreviation for a Watch Dog Timeout (temporary software failure or power

quality problem... this will occur normally after an EPROM upgrade).

WTR LVL An abbreviation for the WATER LEVEL in the storage tank. This is applicable only

with petroleum based products or similar products, where a second and heavier water interface

float is installed on the probe below the product float. Water level is displayed and printed in

level units (inches, or centimeters).

WTR VOL An abbreviation for water volume in the storage tank (this is applicable only in

petroleum based products... where a second and heavier water interface float is installed on

the probe). Water volume is displayed in volume units (gallons or liters).

❖ —