Safety p, Approvals p, Need help ? - names and phone numbers to contact p – Franklin Fueling Systems Tank Sentinel (TS-1001, 2001, 504, 508 & 750) Operators Guide Rev. C User Manual
Page 10

P
Page
P - iv
Tank Sentinel Operator’s Guide
Tank Sentinel
®
Features (
CONTINUED
... )
•
All consoles can communicate with remote computers for off-site notification, management,
and dispatch requests with the
optional
data or fax modem.
•
Access to the Tank Sentinel console door is key-locked for security, and the database /
setup-configuration program mode can be protected by security passwords to protect
the operation and function of the tank gauge.
•
The Tank Sentinel systems can be equipped with many optional accessories or
programs such as: Tank Overfill Alarm and Acknowledge units, SCALD (Statistical and
Continuous Automatic
tank
Leak Detection
testing
).
•
TS-1001/2001 consoles can be upgraded with a unique input code after receipt of a
purchase order and the console serial number. For instance, a 2 tank TS-1001 can be
upgraded to 4 tanks, or SCALD upgrade added either locally on-site, or remotely (remote
upgrade is possible with the
optional
data / fax-modem).
•
All consoles can monitor product lines for leaks when the INCON
TS-LLDI
(Line Leak
Detector) Interface is used. Many line reports can be produced from the collected data,
such as the versatile Regulatory Report.
•
All models can be programmed to use either: 1)
Metric
International System of Units
–
SI Units
(
litres = liters / l / L, centimeters / cm / CM, Celsius / °C / C
)
or
2)
US
English System of
Units
(
gallons / GAL / G, inches / IN, Fahrenheit /
°F / F
)
.
Throughout this manual, the volume length and temperature values are shown in US
Units.
Safety
Intrinsically safe circuits for liquid level probes, and leak detection sensors mounted in:
Class I, Division 1, Group D hazardous locations.
Approvals
All Tank Sentinel models are UL and cUL Listed 6L79 as Liquid Level Gauge / Leak
Detection Systems. Third party approved leak detection — Pd (probability of detection) =
99.2 % for 0.1 or 0.2 gph leak tests (0.1 = precision test, 0.2 is the monthly regulatory
compliance test)
Need Help ? – Names and Phone Numbers to Contact
See the inside front cover of this manual. When you first read this manual, please take
time to fill-in the Contact Names, Phone Numbers and when to contact these people or
organizations (i.e.: local / State EPA Regulatory Agency).
...Reference the Table of Contents for specific topics, and the Glossary for technical
definitions and explanations.
Also be familiar with the Policy and Procedures at your site
and all corrective actions to take should a problem, alarm, or warning occur.
—
❖
—
NOTE
☞