tt
Step 1
uu
If the System 8/10 Plus is already configured for your model of projector, go to
Step 4. If it is
not set up correctly, it will be necessary to change switch settings on the System 8/10 Plus
Main Controller Board. Continue with
Step 2 below to verify the correct configuration.
tt
Step 2
uu
Use a small screwdriver to remove the access cover from the front panel of the System 8/10
Plus. Please refer to the illustration on page 3-3 of your User’s Manual.
___ Before changing anything, remove the AC power cord to the System 8/10 Plus and also turn the
projector’s power off.
tt
Step 3
uu
Using the configuration information which came with your Communications Kit or is on the
switcher’s label, set the System 8/10 Plus switches. The following table and diagram are to
be used only as an example of a typical configuration. Continue with
Step 4 below when your
configuration is correct.
tt
Step 4
uu
Locate the Address DIP switches on the rear panel, lower right, of the switcher. Unless this is
part of a master/slave system, set #3 and #5 to the up position and the others to the down
position.
tt
Step 5
uu
Please refer to the connection diagram and instructions for your projector (see your
System
8/10 Plus Projector Communications Kit instructions). Using the appropriate Communications
Adapter included in your Communications Kit, connect the Comm extension cable from the
Projector Control port of the System 8/10 Plus to the Comm Adapter. Secure the Comm
Adapter to the correct projector port. Connect all other required signal cables according to
the connection diagram.
Config
Model
Rotary Switches
Cable
SW15 Settings
Comm
as
RS1 RS2 RS3 RS4
J2/J3
1
2
3
4
5
6
7
8
9 10
Adapter
✔
Your Model
0
0
F
B
J2
↓ ↓
↑
↓
↑ ↓
↓
↓
↑
↓
26-467-01
Configured For:
RS-232
3
4
5
6
7
8
9
10
1
2
SW15 DIP Switch
ON
RS5 RS2
RS2
RS1
RS3
RS4
RS1