Command

ASCII Command

(host to scaler)

Response

(scaler to host)

Additional Description

Information request

General information

I/i

Vid

X!

•Aud

X!

•Vtyp

X#

•Std

X1)

•Blk

X3!

•Hrt

X1#

•Vrt

X1#

•Pip

X!]

NOTE:

Aud “

X!

” response is a “-” on the non audio model. “Vtyp” returns the detected input type (

X!

*\) .

NOTE:

Blk “

X3!

” response is “0” unless video is muted, then the response is “1”

Query firmware
version

Q/q

x.xx

]

View firmware version.

Query full firmware
version

*Q/*q

x.xx.xxxx

]

View full firmware version details.

Query part number

N/n

zz-zzz-zz

]

View part number.

View internal
temperature

E

20STAT

}

Stat20•

X1!]

Temperature in degrees Celsius.

Backup/restore configuration

NOTE:

{config type} = 0 = IP config (ip.cfg), 1 = event config (event.cfg), 2 = unit specific parameters (box.cfg),

The files are stored on directory /nortxe-backup created on the unit by the “save” commands.

Save device
configuration

E

1*{config type}

XF}

Cfg1*{config

type}]

Save unit configuration to file system.

Restore device
configuration

E

0*{config type}

XF}

Cfg1*{config

type}]

Restore unit configuration from file system.

Product naming

NOTE:

The 24 superscript shown below indicates that the user will get an E24 error on an IP Link-based device

(such as the DVS 605) if the user is not logged in as Administrator when trying to alter names.

Set unit name

24

E

X1@

CN}

Ipn•

X1@]

Set unit name to

X1@

.

Set unit name to
factory default

24

E

•CN}

Ipn•

X10)]

Set unit name to default

X10)

.

View unit name

E

CN}

X1@]

View unit name.

NOTE:

X! = Input selection, 1 to 5

X# = Input video format, 0 = No signal detected (only valid for detected input format query, such as X!*\), 1 = RGB,

2 = YUV Auto, 3 = RGBcvS, 4 = S-video, 5 = Composite, 6 = DVI/HDMI (Only available for IN3, IN4, and IN5)

X1) = Input standard, 0 = No signal detected (current input), 1 = NTSC 3.85, 2 = PAL, 3 = NTSC 4.43, 4 = SECAM

- = N/A (occurs when input is an active RBG, YUV Auto [but not NTSC/PAL], or HDMI signal

X1! = Internal temperature (in degrees Celsius)
X1@ = Unit name is a text string of up to 24 characters drawn from the alphabet (A-Z), digits (0-9), and the minus sign/hyphen (-).
The first character must be an alpha character. The last character must not be a minus. No blank or space characters are
permitted, and no distinction is made between upper- and lowercase.

X1# = Horizontal and vertical frequencies (format is three digit with single decimal and leading zeros for example, 075.3)
X3! = Video mute: 0 = off/disable, 1 = on/enable (mute to black)

X10) = Default name: combination of model name and last 3 pairs of MAC address (for example DVS-605-Series-07-8C-EC)