Command
ASCII Command
(host to scaler)
Response
(scaler to host)
Additional Description
Information request
General information
I/i
Vid
X!
•Aud
X!
•Vtyp
X#
•Std
X1)
•Blk
X3!
•Hrt
X1#
•Vrt
X1#
•Pip
X!]
NOTE:
Aud “
X!
” response is a “-” on the non audio model. “Vtyp” returns the detected input type (
X!
*\) .
NOTE:
Blk “
X3!
” response is “0” unless video is muted, then the response is “1”
Query firmware
version
Q/q
x.xx
]
View firmware version.
Query full firmware
version
*Q/*q
x.xx.xxxx
]
View full firmware version details.
Query part number
N/n
zz-zzz-zz
]
View part number.
View internal
temperature
E
20STAT
}
Stat20•
X1!]
Temperature in degrees Celsius.
Backup/restore configuration
NOTE:
{config type} = 0 = IP config (ip.cfg), 1 = event config (event.cfg), 2 = unit specific parameters (box.cfg),
The files are stored on directory /nortxe-backup created on the unit by the “save” commands.
Save device
configuration
E
1*{config type}
XF}
Cfg1*{config
type}]
Save unit configuration to file system.
Restore device
configuration
E
0*{config type}
XF}
Cfg1*{config
type}]
Restore unit configuration from file system.
Product naming
NOTE:
The 24 superscript shown below indicates that the user will get an E24 error on an IP Link-based device
(such as the DVS 605) if the user is not logged in as Administrator when trying to alter names.
Set unit name
24
E
X1@
CN}
Ipn•
X1@]
Set unit name to
X1@
.
Set unit name to
factory default
24
E
•CN}
Ipn•
X10)]
Set unit name to default
X10)
.
View unit name
E
CN}
X1@]
View unit name.
NOTE:
X! = Input selection, 1 to 5
X# = Input video format, 0 = No signal detected (only valid for detected input format query, such as X!*\), 1 = RGB,
2 = YUV Auto, 3 = RGBcvS, 4 = S-video, 5 = Composite, 6 = DVI/HDMI (Only available for IN3, IN4, and IN5)
X1) = Input standard, 0 = No signal detected (current input), 1 = NTSC 3.85, 2 = PAL, 3 = NTSC 4.43, 4 = SECAM
- = N/A (occurs when input is an active RBG, YUV Auto [but not NTSC/PAL], or HDMI signal
X1! = Internal temperature (in degrees Celsius)
X1@ = Unit name is a text string of up to 24 characters drawn from the alphabet (A-Z), digits (0-9), and the minus sign/hyphen (-).
The first character must be an alpha character. The last character must not be a minus. No blank or space characters are
permitted, and no distinction is made between upper- and lowercase.
X1# = Horizontal and vertical frequencies (format is three digit with single decimal and leading zeros for example, 075.3)
X3! = Video mute: 0 = off/disable, 1 = on/enable (mute to black)
X10) = Default name: combination of model name and last 3 pairs of MAC address (for example DVS-605-Series-07-8C-EC)
DVS 605 • SIS Communication and Control
55