Performing soft system resets, Performing soft system resets (resets 3, 4, and 5) – Extron Electronics MAV Plus Series User Guide User Manual
Page 86
Performing Soft System Resets (Resets 3, 4, and 5) —
CrossPoint Ultra and MAV Plus 88, 128, 816, 164, 168, 1212, 1616, 248, and 328 Matrix Sizes
Perform a soft reset of the switcher as follows:
1.
Use a small screwdriver to press and
hold the rear panel Reset button until the Reset
LED and the front panel Video and Audio buttons blink the number of times for the
desired reset: once (events reset), twice (system reset), or three times (absolute reset)
(see figure 55).
I / O
RGBHV
AUDIO
RESET
RESET
RESET
I / O
RGBHV
AUDIO
RESET
RESET
RESET
I / O
RGBHV
AUDIO
RESET
RESET
RESET
Release, then immediately
press and release again.
Release, then immediately
press and release again.
IP Settings
Reset
6 seconds
Absolute Reset
9 seconds
Press and hold
the Reset button.
3 seconds
Events Reset
Front panel I/O buttons flash once.
Reset LED flashes once.
Release, then immediately
press and release again.
Reset LED flashes twice.
Press and hold
the Reset button.
Press and hold
the Reset button.
Reset LED flashes
three times.
Front panel I/O buttons flash twice.
Front panel I/O buttons flash three times.
(Mode 4)
(Mode 5)
(Mode 3)
Figure 55.
Soft System Resets
2.
Release the Reset button and then immediately press and release the Reset button
again. Nothing happens if the second momentary press does not occur within 1 second.
CrossPoint and MAV Series Matrix Switchers • Operation
80