Ou can also use an, Sis command – Extron Electronics MAV Plus Series User Guide User Manual
Page 103
Command and Response Table for SIS Commands (continued)
Command Function
SIS Command
(Host to Unit)
Response
(Unit to Host)
Additional description
Audio output volume
NOTE: Table 11, below, the commands defines the value of each audio volume step.
Set a specific audio volume
X@
*
X*
V
Out
X@
•Vol
X*]
Example:
1*50v
Out01•Vol50
]
Volume setting for output 7 is 50 (79)%.
Increment volume
X@
+V
Out
X@
•Vol
X*]
Increment volume by 1 step.
Example:
1+V
Out01•Vol51
]
Decrement volume
X@
-V
Out
X@
•Vol
X*]
Decrease volume by 1 step.
Read output volume
X@
V
X*]
Table 6.
Audio Volume Adjustment Settings
41
40
38.5%
40%
dB of
attenuation
Output
volume
63
61
62
60
59
57
58
56
55
53
54
52
51
49
50
48
5.5%
8.5%
7%
76
0%
00
10%
11.5%
14.5%
13%
16%
17.5%
20.5%
19%
22%
23.5%
26.5%
25%
28%
47
45
46
44
43
42
29.5%
32.5%
31%
34%
35.5%
37%
dB of
attenuation
Output
volume
39
38
37
35
36
34
33
31
32
30
29
27
28
26
41.5%
43%
44.5%
47.5%
46%
49%
50.5%
53.5%
52%
55%
56.5%
59.5%
58%
61%
25
23
24
22
21
20
62.5%
65.5%
64%
67%
68.5%
70%
dB of
attenuation
Output
volume
19
17
18
16
15
13
14
12
11
9
10
8
7
5
6
4
71.5%
74.5%
73%
76%
77.5%
80.5%
79%
82%
83.5%
86.5%
85%
88%
89.5%
92.5%
91%
94%
3
1
2
0
95.5%
98.5%
97%
100%
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
value
value
value
X8
X8
X8
NOTE:
X@
= Output number
01
–
16
or
32
X*
= Volume
00
–
64
(1 dB per step except for
0
-to-
1
, which is 13 dB). See table 11, above.
CrossPoint and MAV Series Matrix Switchers • Programming Guide
97