Extron Electronics MAV Plus Series User Guide User Manual
Page 109
Command and Response Table for SIS Commands (continued)
Command Function
SIS Command
(Host to Unit)
Response
(Unit to Host)
Additional description
Names
NOTE: The HTML language reserves certain characters for specific functions (see
Write global preset name
EX(
,
X1!
NG
}
Nmg
X(
,
X1!]
Example:
E
1,Security 1NG
}
Nmg01,Security 1
]
Name global preset 1 “Security 1”.
Read global preset name
EX(
NG
}
X1!]
Example:
E
2NG
}
Security 2
]
Write room preset name
EX1)
*
X(
,
X1!
NP
}
Nmp
X1)
*
X(
,
X1!]
Example:
E
1*3,Podium_DVDNP
}
Nmp01*3,Podium_DVD
]
Name room 1, preset 3 “
Podium_
DVD
”.
Read room preset name
EX1)
,
X(
NP
}
X1!]
NOTES:
•
Do not use leading spaces in preset names.
•
If a preset is unassigned, the
X1!
displays [unassigned].
•
If a global preset is saved, but not yet named, the default name is Preset
X(
.
•
If a room preset is saved, but not yet named, the default name is Rm
X1)
Prst
X(
.
Write input name
EX!
,
X1!
NI
}
Nmi
X$
,
X1!]
Example:
E
1
,
Podium camNI
}
Nmi01
,
Podium cam
]
Name input 1 “Podium cam”.
Read input name
EX$
NI
}
X1!]
Write output name
EX@
,
X1!
NO
}
Nmo
X@
,
X1!]
Example:
E
1,Main PJ1NO
}
Nmo01,Main PJ1
]
Name output 1 “Main PJ1”.
Read output name
EX@
NO
}
X1!]
Front panel locks
NOTE: See
Setting the Front Panel Locks (Executive Modes)
on page 75 for more information on the Lock modes.
Lock all front panel functions
1X
Exe1
]
Enable Lock mode 1.
Lock advanced front panel functions
2X
Exe2
]
Enable Lock mode 2.
Unlock all front panel functions
0X
Exe0
]
Enable Lock mode 0.
View lock status
X
X#]
NOTE:
X!
= Input number (for tie)
00
– (maximum number of inputs for your model) (
00
= untied)
X@
= Output number
01
– (maximum number of outputs for your model)
X#
= Lock mode
0
= mode 0
1
= mode 1
2
= mode 2
X(
= Global or room preset number
00
-
32
,
10
maximum for a room preset (
00
= current configuration for view only)
X1)
= Room number (for room presets)
10
max. (Each can have up to 10 presets (
X(
s) assigned.)
X1!
= Name
12 characters (upper- and lower-case alphanumeric characters and / and spaces) max.
CrossPoint and MAV Series Matrix Switchers • Programming Guide 103