Net port and either an sis command (see – Extron Electronics MAV Plus Series User Guide User Manual
Page 107
Command and Response Table for SIS Commands (continued)
Command Function
SIS Command
(Host to Unit)
Response
(Unit to Host)
Additional description
View ties, gain, volume, mutes, and presets (continued)
View video room preset
configuration
EX1)
*
X(
*
X@
*1VC
}
X!
n
•
X!
n+1
•...•
X!
n+15
•
Vid
]
Show room
X1)
, preset
X(
video
configuration. Show the input (
X!
) tied
to 16 sequential outputs assigned to
room
X1)
, starting from output
X@
.
Command description:
Response description:
room #*room preset #*starting output # (StO#)*1(=video)VC
input # (I#) tied to StO#•I# tied to StO#+1• ... •I# tied to StO#+15•Vid
]
NOTE: The starting output number (
X@
) should always be “
1
” for matrix sizes of 16 outputs or smaller.
View audio room preset
configuration
EX1)
*
X(
*
X@
*2VC
}
X!
n
•
X!
n+1
•...•
X!
n+15
•
Aud
]
Show room
X1)
, preset
X(
audio
configuration. Show the input (
X!
) tied
to 16 sequential outputs assigned to
room
X1)
, starting from output
X@
.
Command description:
Response description:
room #*room preset #*starting output # (StO#)*2(=audio)VC
input # (I#) tied to StO#•I# tied to StO#+1• ... •I# tied to StO#+15•Aud
]
NOTE: The starting output number (
X@
) should always be “
1
” for matrix sizes of 16 outputs or smaller.
Digital Sync Validation Processing (DSVP) (CrossPoint Switchers)
List individual sync frequency
X$
LS
X1#,X1#]
Listed as horizontal frequency, vertical
frequency.
Example:
2LS
031.50
,
060.00
]
Input 2 horizontal frequency is 31.5 khZ
and its vertical frequency is 60 Hz.
NOTE: The matrix switcher returns
000
.
00
,
000
.
00
if there is no connection or sync frequencies are not applicable.
View connections
0LS
X1$
1
X1$
2
X1$
3
...
X1$
n
]
Each
X1$
response is the connection
status (
0
= no input detected,
1
= input detected) of an input, starting
from input 1. n is the maximum
number of inputs for this model.
RGB delay (CrossPoint) Switchers
Set RGB delay
EX@
*
X1%
D
}
Out
X@
•Dly
X1%
*1
]
Example:
E
13*7D
}
Out13•Dly07
]
Set the RGB interval for ties to output
13 to 3.5 seconds (7 x 0.5 sec.).
View RGB delay
EX@
D
}
X1%]
Example:
E
14D
}
05
]
Output 14 interval is 2.5 seconds
(5 x 0.5 sec.).
NOTE:
X!
= Input number (for tie)
00
– (maximum number of inputs for your model) (
00
= untied)
X@
= Output number
01
– (maximum number of outputs for your model)
X$
= Input number (for other than tie)
01
– (maximum number of inputs for your model)
X(
= Global or room preset number
00
-
32
,
10
maximum for a room preset (
00
= current configuration for view only)
X1)
= Room number (for room presets)
10
max. (Each can have up to 10 presets (
X(
s) assigned.)
X1#
= Sync frequency
xxx.xx (frequency in Hz [V] or kHz [H])
X1$
= Connection status
0
= no input connected
1 = input connected
X1%
= RGB delay interval
Delay in 1/2 second increments (
10
maximum)
CrossPoint and MAV Series Matrix Switchers • Programming Guide 101