beautypg.com

Net port and either an sis command (see – Extron Electronics MAV Plus Series User Guide User Manual

Page 107

background image

Command and Response Table for SIS Commands (continued)

Command Function

SIS Command

(Host to Unit)

Response

(Unit to Host)

Additional description

View ties, gain, volume, mutes, and presets (continued)

View video room preset
configuration

EX1)

*

X(

*

X@

*1VC

}

X!

n

X!

n+1

•...•

X!

n+15

Vid

]

Show room

X1)

, preset

X(

video

configuration. Show the input (

X!

) tied

to 16 sequential outputs assigned to
room

X1)

, starting from output

X@

.

Command description:
Response description:

room #*room preset #*starting output # (StO#)*1(=video)VC
input # (I#) tied to StO#•I# tied to StO#+1• ... •I# tied to StO#+15•Vid

]

NOTE: The starting output number (

X@

) should always be “

1

” for matrix sizes of 16 outputs or smaller.

View audio room preset
configuration

EX1)

*

X(

*

X@

*2VC

}

X!

n

X!

n+1

•...•

X!

n+15

Aud

]

Show room

X1)

, preset

X(

audio

configuration. Show the input (

X!

) tied

to 16 sequential outputs assigned to
room

X1)

, starting from output

X@

.

Command description:
Response description:

room #*room preset #*starting output # (StO#)*2(=audio)VC
input # (I#) tied to StO#•I# tied to StO#+1• ... •I# tied to StO#+15•Aud

]

NOTE: The starting output number (

X@

) should always be “

1

” for matrix sizes of 16 outputs or smaller.

Digital Sync Validation Processing (DSVP) (CrossPoint Switchers)

List individual sync frequency

X$

LS

X1#,X1#]

Listed as horizontal frequency, vertical
frequency.

Example:

2LS

031.50

,

060.00

]

Input 2 horizontal frequency is 31.5 khZ
and its vertical frequency is 60 Hz.

NOTE: The matrix switcher returns

000

.

00

,

000

.

00

if there is no connection or sync frequencies are not applicable.

View connections

0LS

X1$

1

X1$

2

X1$

3

...

X1$

n

]

Each

X1$

response is the connection

status (

0

= no input detected,

1

= input detected) of an input, starting

from input 1. n is the maximum
number of inputs for this model.

RGB delay (CrossPoint) Switchers

Set RGB delay

EX@

*

X1%

D

}

Out

X@

•Dly

X1%

*1

]

Example:

E

13*7D

}

Out13•Dly07

]

Set the RGB interval for ties to output
13 to 3.5 seconds (7 x 0.5 sec.).

View RGB delay

EX@

D

}

X1%]

Example:

E

14D

}

05

]

Output 14 interval is 2.5 seconds
(5 x 0.5 sec.).

NOTE:

X!

= Input number (for tie)

00

– (maximum number of inputs for your model) (

00

= untied)

X@

= Output number

01

– (maximum number of outputs for your model)

X$

= Input number (for other than tie)

01

– (maximum number of inputs for your model)

X(

= Global or room preset number

00

-

32

,

10

maximum for a room preset (

00

= current configuration for view only)

X1)

= Room number (for room presets)

10

max. (Each can have up to 10 presets (

X(

s) assigned.)

X1#

= Sync frequency

xxx.xx (frequency in Hz [V] or kHz [H])

X1$

= Connection status

0

= no input connected

1 = input connected

X1%

= RGB delay interval

Delay in 1/2 second increments (

10

maximum)

CrossPoint and MAV Series Matrix Switchers • Programming Guide 101

This manual is related to the following products: