Special characters, See the, Set serial ports – Extron Electronics MAV Plus Series User Guide User Manual
Page 115: Parameters
Command and Response Table for IP- and Remote-Port-Specific SIS Commands (continued)
Command Function
SIS Command
(Host to Unit)
Response
(Unit to Host)
Additional description
IP and Remote port setup commands (continued)
Set e-mail events for recipient
EX4!
,
X4#
,
X4$
,
X4$
,
...
,
X4$
EM
}
You must first have set an e-mail
recipient for the e-mail account number
(
X4!
), using the separate Set e-mail (CR)
command (see the previous page).
Ipe
X4%]
Example:
CrossPoint 450 Plus 3232
E
72,3,1,2,8,32,98,99,EM
}
]
E-mail account #72, JSmith, will
receive fail/missing and fixed/restored
messages for input signals 1, 2, 8, and
32; fans; and power supplies.
Read e-mail event notifications for
one account (recipient)
EX4!
EM
}
X4$
,
X4$
,
X4$
, ... ,
X4$]
Response description:
Notify-what?,Inputs 1-32 (inputs above the matrix size are always zero),fans,PS
]
Example:
CrossPoint 450 Plus 3232
EX4!
EM
}
See below
Response:
Notify failed and fixed
3, 1 1 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
01
Input:
02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
Fans
Power Supplies
E-mail input 8 status
E-mail power supply and fan status
Ignore input 16
0 0 0 0 0 0 0 0 1 1 1
Example:
MAV Plus 1616
EX4!
EM
}
See below
Response:
Notify failed and fixed
3, 1 1 0 0 0 0 0 1 0 0 0 0 0 0 0 0 1
01
Input:
02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 Power Supply
E-mail input 8 status
Ignore input 16
Set DHCP on or off
EX4^
DH
}
Idh
X4^]
Default: 0 (Off)
Read DHCP on/off status
E
DH
}
X4^]
Set serial port parameters
EX4&
*
X4*
,
X4(
,
X5)
,
X5!
CP
}
Cpn
X4&
•Ccp
X4*
,
X4(
,
X5)
,
X5!]
Read serial port parameters
EX4&
CP
}
X4*
,
X4(
,
X5)
,
X5!]
Configure flow control
EX4&
*
X5$
,
X8&
CF
]
Cpn
X4&
•Cfl
X8^
,
X5%]
Read flow control
EX4&
CF
]
X5$
,
X5%]
Configure receive timeout
EX4&
*
X5^
,
X8(
CE
]
Cpn
X4&
•Cce
X8*
,
X5&]
Read receive timeout
EX4&
CE
]
X5^
,
X5&]
Set mode
EX4&
*
X5@
CY
}
Cpn
X4&
•Cty
X5@]
Read mode
EX4&
CY
}
X5@]
Set verbose mode
EX5#
CV
}
Vrb
X5#]
Read verbose mode
E
CV
}
X5#]
Configure current port timeout
E
0*
X5*
TC
}
Pti0*
X5*]
Read current port timeout
E
0TC
}
X5*]
Configure global IP port timeout
E
1*
X5*
TC
}
Pti1*
X5*]
Read global IP port timeout
E
1TC
}
X5*]
Special Characters
The HTML language reserves certain characters for specific functions. The switcher does
not accept these characters as part of names, passwords, or locally created file names.
The switcher following characters are invalid or not recommended:
{space (spaces
are ok for names)} + ~ , @ = ‘ [ ] { } < > ’ “ semicolon (;) colon (:) |
\ and ?.
CrossPoint and MAV Series Matrix Switchers • Programming Guide 109