Sis command – Extron Electronics MAV Plus Series User Guide User Manual
Page 102
Command and Response Table for SIS Commands (continued)
Command Function
SIS Command
(Host to Unit)
Response
(Unit to Host)
Additional description
Read ties
NOTE: The
&
read tie command for RGB and the
%
read tie command for video can be used interchangeably on the matrix switchers.
Read RGB (video) output tie
X@
&
X!]
RGB input
X!
is tied to output
X@
.
Read video output tie
X@
%
X!]
Video input
X!
is tied to output
X@
.
Read audio output tie
X@
$
X!]
Audio input
X!
is tied to output
X@
.
Video mutes
RGB or video mute
X@
*1B
Vmt
X@
*1
]
Mute output
X@
video (video off).
RGB or video unmute
X@
*0B
Vmt
X@
*0
]
Unmute output
X@
video (video on).
Read RGB or video mute
X@
B
X#]
X#
=
1
= enable (muted)
0
= disable (unmuted) (
default).
Global RGB or video mute
1*B
Vmt1
]
Mute all video outputs.
Global RGB or video unmute
0*B
Vmt0
]
Unmute all video outputs.
Audio input gain and attenuation
NOTE: The set gain (
G
) and set attenuation (
g
) commands
are case sensitive.
Set audio input gain to +dB value
X$
*
X%
G
In
X$
•Aud
X^]
Example:
1*2G
In01•Aud+02
]
Set input 1 audio gain to +2 dB.
Set audio input attenuation to -dB
value
X$
*
X&
g
In
X$
•Aud
X^]
Increment gain
X$
+G
In
X$
•Aud
X^]
Increase gain by 1 dB.
Example:
5+G
In05•Aud+03
]
Increase audio input 5 level from +2 dB
to +3 dB.
Decrement gain
X$
-G
In
X$
•Aud
X^]
Decrease gain by 1 dB.
Example:
7-G
In07•Aud-09
]
Decrease audio input 7 level from -8 dB
to -9 dB.
Read input gain
X$
G
X^]
Example:
3G
-06
]
Audio input 3 level is at -6 dB.
NOTE:
X!
= Input number (for tie)
00
– (maximum number of inputs for your model) (00 = untied)
X@
= Output number
01
– (maximum number of outputs for your model)
X#
= Mute status
0
= off (unmuted)
1
= on (muted)
X$
= Input number (for other than tie)
01
– (maximum number of inputs for your model)
X%
= Audio gain
0
–
24
(1 dB per step)
X^
= Numeric dB value
–18
to
+24
(45 steps of gain or attenuation) (Default = 0 dB)
X&
= Audio attenuation
1
–
18
(1 dB per step)
CrossPoint and MAV Series Matrix Switchers • Programming Guide