If desired, adjust any of these values as follows:
1.
Click in the desired field. The field changes to an editable field appropriate to the value
being change and the graphic cursor becomes a text cursor.
•
The
Date
field becomes a set date field, with the date in the
format (M)M/(D)D/YYYY. Leading zeroes are not shown.
•
The
Time (local)
field becomes a set time field, with the
time in the format HH:MM:SS (00:00:00 to 23:59:59).
•
The
GMT
field becomes a set offset field, with the offset in the format
±HH:MM (–12:00 to +14:00).
2.
Edit the field as desired to set the proper proper value. For time, remember to use
24-hour time. Leading zeroes are optional.
3.
Press the
4.
Click the
Take
button to make the date change take affect.
Sync Time to PC button
Clicking the
Sync Time to PC
button causes the computer you are operating to send its
internal time to the switcher in a set time command.
Use Daylight Saving check box
Click in the
Use Daylight Saving
checkbox to turn Daylight Saving Time on and off for
North America. When Daylight Saving Time is turned on, the switcher automatically updates
its internal clock between Standard Time and Daylight Saving Time in the spring and fall
on the date that the time change occurs in North America. When Daylight Saving Time is
turned off, the switcher does not adjust its time reference.
NOTE: For Daylight Saving Time in Europe and Brazil, see to the
Administrator Password and User Password fields
The Administrator Password field displays the password required to log on to the matrix
switcher via the Ethernet port with all of the rights and privileges of the administrator. The
User Password field displays the password required to log on to the matrix switcher via
the Ethernet port as a user, without all of the rights and privileges of the administrator.
Passwords are case sensitive and are limited to 12 upper-case and lower-case
alphanumeric characters.
Both password fields are masked with asterisks (************) as a security measure.
NOTES:
•
Editing the Administrator Password field while connected via the Ethernet port can
immediately disconnect the user from the switcher. Extron recommends editing
this field using either serial port and protecting the Ethernet access to this screen
by assigning an administrator password to qualified and knowledgeable personnel
only.
•
An administrator password must be created before a user password can be
created.
•
The HTML language reserves certain characters for specific functions (see
CrossPoint and MAV Series Matrix Switchers • Matrix Software 117