Command and response table for, Ip- and remote port specific, Commands – Extron Electronics MAV Plus Series User Guide User Manual
Page 113: Sis commands, Symbol definitions

Command and Response Table for
IP- and Remote Port Specific
SIS Commands
Symbol definitions
X3)
= Matrix name
(Up to 24 alphanumeric characters)
NOTE: The HTML language reserves certain characters for specific functions (see
on page 109).
X3!
= Default name
Model name
+ last 3 pairs of MAC address.
nn
= 16 or 32.
X3@
= Time and date (for set)
In the format: MM/DD/YY•HH:MM:SS where:
MM = month:
01
(January) through
12
(December)
DD =
01
through
31
YY =
00
through
99
HH =
00
through
23
MM =
00
through
59
SS =
00
through
59
X3#
= Time and date (for read)
In the format: Day,•DD•Mmm•YYYY•HH:MM:SS where:
Day of the week:
Mon
through
Sun
DD =
01
through
31
Mmm = month:
Jan
through
Dec
YYYY =
2000
through
2099
HH =
00
through
23
MM =
00
through
59
SS =
00
through
59
X3$
= GMT offset
–12
.
0
through
+14
.
0
. Hours and minutes removed from GMT
X3%
= Daylight Savings Time
0
= Daylight Savings Time off or ignore
1
= Daylight Savings Time on (North America)
2
= Daylight Savings Time on (Europe)
3
= Daylight Savings Time on (Brazil)
X3^
= IP address
###.###.###.###
X3&
= Hardware (MAC) address
##-##-##-##-##-##
X3*
= Number of open connections
000
-
200
X3(
= Password
Up to 12 alphanumeric characters
NOTE: The HTML language reserves certain characters for specific functions (see
on page 109).
X4)
= Domain name
Standard domain name rules apply (for example: xxx.com)
NOTE: The HTML language reserves certain characters for specific functions (see
on page 109). The @ character is
acceptable only as the lead-in to the domain name (such as @extron.com).
X4!
= E-mail account
65
-
72
.
65
= e-mail recipient 1,
66
= 2,
67
= 3, ...
72
= recipient #8
X4@
= E-mail address
Typical e-mail address format (for example: [email protected])
X4#
= Notify when?
0
= no response
3
= both 1 & 2
1
= fail or missing
4
= suspend
2
= fixed or restored
X4$
= Notification selections
Matrix size 2412 and larger:
01
-
32
= input 1 through input 32
98
= power supplies
99
= fans
Matrix size 1616 and smaller:
01
-
17
= input 1 through input 16
17
= power supply
X4%
= Notify status (for read)
34- or 17-digit number. For each digit:
0
= do not notify,
1
= notify
X4^
= DHCP
0
= off,
1
= on
X4&
= Port number
00
= All ports
01
= Rear panel Remote RS-232/RS-422 port
02
= Front panel Configuration port
X4*
= Baud rate
9600
,
19200
,
38400
,
115200
X4(
= Parity
odd, even, none, mark, space (only the first letter required)
X5)
= Data bits
7
,
8
X5!
= Stop bits
1
,
2
X5@
= Port type
0
= RS-232
1
= RS-422
CrossPoint and MAV Series Matrix Switchers • Programming Guide 107