2 ordering – GE Industrial Solutions GERAPID 8007R, 10007R WITH ARC CHUTES 1X2, 1X3 User Manual
Page 36

7.2 Ordering.
Please fill in yellow cells for order description. Options preview in chapter 7.1.
Gerapid
with arc chute
APN460437 rev03 09/2009
Quantity
to
Diagram no:
Opt
Code
Code
1
1
5
2
2
6
3
3
7
4
4
5
6
1
4
7
2
5
8
3
6
9
S
E
10
1
7
11
2
8
12
3
9
13
4
A
14
5
B
15
6
R
16
1
5
17
2
6
18
3
R
19
4
20
B
21
S
22
1
0
23
2
24
1
25
2
0
26
1
5
27
2
6
28
3
7
29
4
8
30
kA
kA
kA
kA
kA
kA
0
31
kA
kA
kA
kA
kA
kA
32
1
4
33
2
5
34
3
R
35
1
4
36
2
R
37
3
38
0
39
[KSM]: code 10
1
40
0
4
41
1
5
42
2
6
43
3
44
0
2
45
[EDA]: code 12
1
3
46
0
47
[ZWA]: code 13
1
48
0
49
[STA]: code 14
1
50
0
2
51
[SCH]: code 15
1
52
0
53
[HAN]: code 16
1
54
0
55
[LBM]: code 17
1
56
0
57
[ZAL]: code 18
1
58
1
3
59
2
4
60
[SST]: code 19
R
61
1
4
62
2
63
[CUS]: code 20
3
R
64
En
Ch
65
De
R
Need a special reference no. on the nameplate ? =>
Polarized adjust. 2 kA - 6 kA
Polarized adjust. 4 kA - 8 kA
Standard Zero Voltage Release
Without OCT
On Request
230 V AC
240 V AC
Special type B
Special type S
For SEL 6 kA
For SEL 12 kA
On Request
H/V - (V)ertical
On Request
Gerapid 4207
Name
Breaker type
Gerapid 2607
[BAU]: code 1
Code Name
Gerapid 6007
Gerapid 8007
60 V DC
48 V DC
220 V DC
110 V DC
125 V DC
1X2 (1000 V)
1X3 (1500 V)
2X2 (2000 V)
Shunt Trip - external 125 V DC
88 .. 145 V DC
125 .. 353 V DC / 115 .. 240 V AC
10 convertible contacts
Ta = 55 °C
external 24 V DC±5%
Polarized adj. 0,4 kA - 1,2 kA
Main terminals layout
Top/Bottom
Top connector '+'
Main terminals polarization
H/H - (H)orizontal
V/V
[ANS]: code 4
Polarized adjust. 0,8 kA - 2,5 kA
33 .. 85 V DC
Adjustable up to 15 kA
-
24 V/24 V (DC stabilizer)
Adjustable up to 24 kA
Fixed setting up to 24 kA
3 convertible contacts
[KSA]: code 7
[NET]: code 8
Control circuits supply voltage
Requested marks on the scale
Protection options
Lever for manual operating
Arc chute presence
Railway DC acc. EN50123-2
Auxiliary tripping releases
Shunt Trip - external 110 V DC
[STE]: code 3
Auxiliary contacts quantity
Without
[HIL]: code 11
OC trip target
[HIS]: code 9
[POL]: code 5
SEL operation temperature
[TSEL]: code 6
OC release
Threshold [kA]
Gearapid SE retrofit
Mechanical Counter
Control connectors type
Railway & Industry applications
Counter
Heavy Industry type
LV DC acc. IEC60947-2
Standard Shunt Trip
Shunt Trip - external 220 V DC
Chinese
V/H
Fixed setting up to 15 kA
Ta = 35 °C
Top connector '-'
250 V DC
without SEL
Not apply
German
Catalogue no:
Arc chute type
[LIC]: code 2
1X4 (2000 V)
2X2 S (1500 V)
With
Without
Sidewalls protection panels
Without
Rodent proofing
Closing solenoid supply voltage
Without
5 convertible contacts
With
Without
9 convertible contacts
Forced tripping release
Without
Impulse coil w/o internal C-bank
Contact position indicator
ED impulse coil release
Without
With
With
With
Without
Without
Relevant standard
China acc. IEC947-2 & GB14048.2
Military type acc. MIL-C-5015G
English
Documentation Language
LV DC acc. IEEEC37.14
[LNG]:
Name
Gerapid 8007R
Gerapid 10007R
Gerapid 8007DS
Impulse coil with internal C-bank (NEKO)
-
2X3 (3000 V)
2X4 (3600 V)
EF4-12 (3600 V)
110 V AC
120 V AC
On request
Check if "On Request" options required.
Breaker number:
Check if special customer's ratings required.
On Request
On Request
On Request
125 V AC
=>
=>
36
Design and specifications are subject to change without notice
DTR01807 rev.02 2010-02-16