Table 7. General options overview for Gerapid breakers.
Breaker type
Code number:
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Relevant standards
1 Gerapid 2607
5 Gerapid 8007R
LV DC acc. IEC60947-2 4
Railway DC acc. EN50123-2 1
2 Gerapid 4207
6 Gerapid 10007R
On Request R
LV DC acc. IEEEC37.14 2
3 Gerapid 6007
7 Gerapid 8007DS
China acc. IEC947-2 & GB14048.2 3
4 Gerapid 8007
code 19
Control connectors type
Arc chute type
Code 2
Gearapid SE retrofit 3
Railway & Industry applications 1
1 1X2 (1000 V)
4 2X2 (2000 V)
S 2X2 S (1500 V)
Heavy Industry type 4
Military type acc. MIL-C-5015G 2
2 1X3 (1500 V)
5 2X3 (3000 V)
E EF4-12 (3600 V)
R
3 1X4 (2000 V)
6 2X4 (3600 V)
Code 18
Counter
Closing solenoid supply voltage
Code 3
Mechanical Counter 1
Without 0
1 48 V DC
5 220 V DC
9 125 V AC
2 60 V DC
6 250 V DC
A 230 V AC
3 110 V DC
7 110 V AC
B 240 V AC
Code 17
Arc chute presence signal
4 125 V DC
8 120 V AC
R On Request
With 1
Without 0
Main terminals layout (Top / Bottom)
Code 4
Code 16
Lever for manual operating
1 H/H - (H)orizontal
4 V/V
B Special type B
With 1
Without 0
2 H/V - (V)ertical
5 For SEL 6 kA
S Special type S
3 V/H
6 For SEL 12 kA
R On Request
Code 15
Protection options
Main terminals polarization
Code 5
Sidewalls protection panels 1
Without 0
1 Top connector '+'
2 Top connector '-'
0
Not apply
Rodent proofing 2
SEL operation temperature
Code 6
Code 14
Contacts position indicator
1 Ta = 35 °C
0 without SEL
With 1
Without 0
2 Ta = 55 °C
Code 13
Forced tripping release
Over current release (OCT)
Code 7
With 1
Without 0
1 Fixed setting up to 15 kA
5 Polarized adj. 0,4-1,2 kA
0
2 Adjustable up to 15 kA
6 Polarized adjust. 0,8-2,5 kA
Code 12
Impulse coil release
3 Fixed setting up to 24 kA
7 Polarized adjust. 2-6 kA
Impulse coil with internal C-bank (NEKO) 2
Without 0
4 Adjustable up to 24 kA
8 Polarized adjust. 4-8 kA
- 3
Impulse coil w/o internal C-bank 1
Control circuits supply voltage
Code 8
Code 11
Auxiliary tripping device
1 external 24 V DC±5%
4 88 .. 145 V DC
Shunt Trip - external 125 V DC 4
Without 0
2 24 V/24 V (DC stabilizer)
5 125 .. 353 V DC / 115 .. 240 V AC
Shunt Trip - external 220 V DC 5
- 1
3 33 .. 85 V DC
R On request
Standard Zero Voltage Release 6
Standard Shunt Trip 2
0 R
Shunt Trip - external 110 V DC 3
Auxiliary contacts quantity - changeover type
Code 9 Code 10
OC trip target
1 3 convertible contacts
3 9 convertible contacts
R On Request
With 1
Without 0
2 5 convertible contacts
4 10 convertible contacts
Without
OCT
7.1 Options overview.
•
The coding system,
introduced in 2008, is a
catalog configuration tool
based on Excel®.
•
The catalogue code consists
of 20 digits. Each digit
represents specific rated
value or component.
•
Table 7 shows all available
values, components and
accessories for the Gerapid
breaker family. Detailed
descriptions are available in
section 3. Please contact GE
Sales representative in case of
any questions.
•
The coding system is valid for
Gerapid feeder type (F),
rectifier type (R) and
disconnector type (DS). This
User Manual relates only to
standard, feeder type
breakers (F).
•
Not all of the options from
Table 7 are compatible. To
avoid improper configurations
use the “Gerapid
configuration tool” for
ordering.
•
This Excel® based tool
provides a quick and mistake
proof configuration with
automatic generating of the
proper catalogue code and
set of characteristics helpful
for order description. Ask your
GE Representative for details.
The number of this tool is:
APN460437.
2010-02-16 DTR01807 rev.02
Design and specifications are subject to change without notice
35