Control box terminals
(1) 12-pole
AC 400 V, 20 A
(4) 15-pole
AC 250 V, 8 A
Closing solenoid drive
1)
Rated voltage
AC 110 V - 240 V and DC 60 V - 250 V
Operating range
80 % - 115 % of rated voltage
Power consumption 60 Vdc drive
3000 W
Power consumption all other voltages
4500 W
Minimum command signal time
100 ms
Minimum interval between two closing operations ~8 s w/o NEKO installed; ~14 s with NEKO
Internal voltage converter
1)
Input: Voltage range
DC 33 - 85 V
Output: Voltage range
DC 24 V (±5%)
Current
6 A continuous
Model description
PCMD 150 48 S24W-GE
Input: Voltage range
DC 88 - 145 V
Output: Voltage range
DC 24 V (±5%)
Current
6 A continuous
Model description
PCMD 150 110 S24W-GE
Input: Voltage range
AC 115 - 240 V, DC 125 - 353 V
Output: Voltage range
DC 24 V (±5%)
Current
3 A continuous, 5 A for 100 ms
Model description
PCMA 70 S24W-GE or PCMAS 75 S24-GE
External power supply
with plug and socket unit
requires filtered DC 24 V (±5%)
Aux. contact HS 1…HS 10,
Rated operational voltage Ue/AC
230 V
OC trip target (code 10)
Rated operational current Ie/AC-15
1 A
Arc chutes indicator (code 17)
Conventional thermal current Ie/AC-12 (Ith)
10 A
Rated operational voltage Ue/DC
110 V / 220 V
Rated operational current Ie/DC-13
0.5 A / 0.3 A
Minimum current/voltage ratings
0,1 mA / 6 V DC
Contact duty (min. value)
DC 10 V / 2 mA
Shunt trip (a-release)
Rated voltage/power Uc/Pc
24 V / 100 W
Operating range: OFF
21.6 V - 26.4 V
UVR (r-release)
Rated voltage Uc
24 V
Zero voltage release
Operating range: OFF
< 4 V
Operating range: ON
24 V (±10%)
Power consumption
~ 10 W
ED impulse release
Energie source: Capacity
2000 µF
Charging voltage
300 V
Switching interval
max. 1/min with 10 consecutive operations
Endurance
1 000 operations with 1 operation per 180 s
Firing signal level / duration
6 - 24 V / 100 - 1000 ms
Charging signalization relay AC duty :
AC 250 V/ 0.5 A - AC 120 V /1 A
DC duty : DC 220V/0.1A - DC 125V/0.3A - DC 10V/3A
1)
Standard ambient conditions acc. to EN 50123-1 Attachement B. For meeting outside of this standard range, please contact GE.
Table 2a: Technical data of auxiliary circuits
Components
Technical datas of control circuits
Us / In
Closing
push-button -S1 (-X2 :4 / :5)
DC 24 V / approx. 10 mA
ST releasing
push-button-S2 (-X2 :6 / :7)
DC 24 V / approx. 4 A
UVR releasing
push-button -S2 ( -X2 :6 / :7)
DC 24 V / approx. 10 mA
push-button -S2 ( -X2 :8 / :9 )
DC 24 V / approx. 450 mA
Impulse coil tripping w/o NEKO
push-button -S3 (R=0.18 Ohm, Tau = 0.5ms)
DC 300 V / ~1100 A / 3 ms
Impulse coil tripping with NEKO
"firing signal" at ( -X2 :10 / :11 )
DC 6 V…24 V / approx.20 mA
Table 2b: Control circuits ( directional values to rate the components )
12
Design and specifications are subject to change without notice
DTR01807 rev.02 2010-02-16