06 name servers, N-07 domain name, 08 host name – GE Industrial Solutions AF-650 GP PROFINET User Manual
Page 44: 09 physical address, En-09 physical address, N-10 link status, N-11 link duration, 12 auto negotiation, N-13 link speed, N-14 link duplex

EN-06 Name Servers
Range:
Function:
0 N/A
*
[0 - 2147483647 N/A] IP addresses of Domain Name
Servers. Can be automatically
assigned when using DHCP.
EN-07 Domain Name
Range:
Function:
0 N/A [0 - 2147483647 N/A] Domain name of the attached
network. Can be automatically
assigned when using DHCP.
EN-08 Host Name
Range:
Function:
0 N/A
[0 - 0 N/A]
Logical (given) name of option.
NOTE
Please note that the display of the drive will only show the
first 19 characters, but the remaining characters are stored
in the drive.
EN-09 Physical Address
Range:
Function:
0 N/A
*
[0 - 0 N/A] Read only Displays the Physical (MAC)
address of the option.
EN-1# Ethernet Link parameters
Option:
Function:
Applies for whole parameter group.
[0]
Port 1
[1]
Port 2
EN-10 Link Status
Option:
Function:
Read only. Displays the link status of the Ethernet
ports.
[0]
*
No Link
[1]
Link
EN-11 Link Duration
Range:
Function:
0 N/A
*
[0 - 0 N/A] Read only. Displays the duration of the
present link on each port in dd:hh:mm:ss.
EN-12 Auto Negotiation
Option:
Function:
Configures Auto Negotiation of Ethernet link
parameters, for each port: ON or OFF.
[0]
Off
Link Speed and Link Duplex can be configured in
EN-13 Link Speed and EN-14 Link Duplex.
[1]
*
On
NOTE
It is recommended to set EN-12 Auto Negotiation to OFF [0]
for the PROFINET option and for the connected port. This
will ensure that the connected ports will be set to an
optimized Link Speed with Link Duplex setting. If only one
of the ports in a link is set to Auto Negotiation ON, it can
course the ports to switch to half duplex, resulting in poor
network performance. Most switches today have Auto
negotiation set, but this can lead to a longer time to
establish a connection.
EN-13 Link Speed
Option:
Function:
Forces the link speed for each port in 10 or 100
Mbps. If EN-12 Auto Negotiation is set to: ON,
this parameter is read only and displays the
actual link speed. “None” is displayed if no link
is present.
[0]
*
None
[1]
10 Mbps
[2]
*
100 Mbps
EN-14 Link Duplex
Option:
Function:
Forces the duplex for each port to Full or Half
duplex. If EN-12 Auto Negotiation is set to: ON,
this parameter is read only.
[0]
Half Duplex
[1]
*
Full Duplex
EN-80 FTP Server
Option:
Function:
[0]
*
Disabled
Disables the built-in FTP server.
[1]
Enabled
Enables the built-in FTP server.
EN-81 HTTP Server
Option:
Function:
[0]
*
Disabled
Disables the built-in HTTP (web) server.
[1]
Enabled
Enables the built-in HTTP (web) server.
EN-82 SMTP Service
Option:
Function:
[0]
*
Disabled Disables the SMTP (e-mail) service on the option.
[1]
Enabled
Enables the SMTP (e-mail) service on the option.
EN-89 Transparent Socket Channel Port
Range:
Function:
4000
N/A
*
[0 - 65535
N/A]
Configures the TCP port number for
the transparent socket channel. This
enables Drive messages to be sent
transparently on Ethernet via TCP.
Default value is 4000, 0 means
Parameters
PROFINET Operating Instruction
43
8
8