beautypg.com

Esr901, Erminal, Lock – B&B Electronics ESR904 - Manual User Manual

Page 83: Out in, Rs-422

background image

RS-422 Connections

Manual Documentation Number: ESR90x-5012m

Appendix B

73

B&B Electronics Mfg Co Inc – 707 Dayton Rd - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com

B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com

ESR901 Terminal Block Pin-out in RS-422 Mode

GN

D

CT

S/T

X-

TX

/TX+

RX

/RX

+

RT

S/RX

-

1

2

3

4

5

Signal Name

RS-422

Direction

Terminal

Signal Ground

GND

---

1

Transmit Data (-)

TXD(-)

Out

2

Transmit Data (+)

TXD(+)

Out

3

Receive Data (+)

RXD(+)

In

4

Receive Data (-)

RXD(-)

In

5

Figure 52. ESR901 Terminal Block Pin-out in RS-232 Mode

In the RS-422 mode, TXD lines are outputs and RXD lines are inputs.
Connect the Serial Server TXDB(+) line to the RXDB(+) line of the serial
device, and the Serial Server TXDA(-) to the RXDA(-) of the serial device.

If Flow Control is set for RTS/CTS, connect the Serial Server RTSB(+) to
CTSB(+) of the serial device and the Serial Server RTSA(-) line to the
CTSA(-) of the serial device. Connect from the Serial Server CTSB(+) line to
the RTSB(+) of the serial device and from the Serial Server CTSA(-) line to
the RTSB(+) line of the serial device.

If connecting to Receive Only RS-422 devices, connect from the Serial
Server TXDB(+) and TXDA(-) lines to the receive pairs on all serial devices.

Ground is signal ground and provides a common mode reference for the RS-
422 Receiver and Transmitters.