Drying time table – Grain Systems PNEG-1915 User Manual
Page 67

1. Drying Time Table
PNEG-1915 VN2 Portable Dryer Drying Charts for All Models of Vision
67
Drying Time Table……..2420 and 1000 (Continued)
Wheat, Barley, Milo...Dry and Cool (#1 and #2 Cooling)
Soybeans...Dry and Cool (#1 and #2 Cooling)
Canola...Dry and Cool
The above drying capacities are estimates based on drying principles, field results and computer
simulations. Variances may occur due to grain physiological factors (kernel size, chemical composition,
variety, maturity), excessive fines, weather conditions, etc.
140°F
155°F
175°F
Moisture
% Unload
Rate
Dry Time
(Min.)
Capacity
Dry (BPH)
% Unload
Rate
Dry Time
(Min.)
Capacity
Dry (BPH)
% Unload
Rate
Dry Time
(Min.)
Capacity
Dry (BPH)
% In
% Out
15
13
32
33
886
37
28
1033
44
24
1230
16
13
24
43
668
28
37
779
33
31
927
17
13
20
53
544
23
46
635
27
38
756
18
13
17
63
462
19
54
539
23
45
642
19
13
15
72
402
17
62
469
20
52
558
20
13
13
82
354
15
70
413
18
59
492
21
13
11
92
314
13
79
367
16
66
437
23
13
9
115
251
11
99
293
13
83
348
25
13
7
143
202
9
123
236
10
103
281
120°F
130°F
140°F
Moisture
% Unload
Rate
Dry Time
(Min.)
Capacity
Dry (BPH)
% Unload
Rate
Dry Time
(Min.)
Capacity
Dry (BPH)
% Unload
Rate
Dry Time
(Min.)
Capacity
Dry (BPH)
% In
% Out
15
13
36
29
1004
41
25
1147
47
22
1291
16
13
27
38
757
31
33
865
35
30
973
17
13
22
47
617
25
41
705
29
36
793
18
13
19
55
524
22
48
599
24
43
674
19
13
16
64
456
19
56
521
21
49
586
20
13
14
72
401
17
63
459
19
56
516
21
13
13
81
356
15
71
407
17
63
458
23
13
10
102
284
12
89
325
13
79
366
25
13
8
126
229
9
111
262
11
98
294
Drying table based on 100% unload rate of…...2772 BPH
120°F
140°F
160°F
Moisture
% Unload
Rate
Dry Time
(Min.)
Capacity
Dry (BPH)
% Unload
Rate
Dry Time
(Min.)
Capacity
Dry (BPH)
% Unload
Rate
Dry Time
(Min.)
Capacity
Dry (BPH)
% In
% Out
11
9
29
36
802
37
28
1031
45
23
1260
12
9
22
48
604
28
37
777
34
30
950
13
9
18
59
493
23
46
633
28
37
774
14
9
15
69
419
19
54
538
24
44
658
15
9
13
80
364
17
62
468
21
51
572
16
9
12
90
321
15
70
412
18
57
504
17
9
10
102
285
13
79
366
16
65
447
18
9
9
114
254
12
89
326
14
73
399
19
9
8
128
227
11
99
292
13
81
357
Drying table based on 100% unload rate of…...2772 BPH