Drying time table – Grain Systems PNEG-1915 User Manual
Page 31
![background image](/manuals/277758/31/background.png)
1. Drying Time Table
PNEG-1915 VN2 Portable Dryer Drying Charts for All Models of Vision
31
Drying Time Table……..1214S and 2141 (Continued)
Wheat, Barley, Milo...Dry and Cool (#1 Cooling)
Soybeans...Dry and Cool (#1 Cooling)
Canola...Dry and Cool
The above drying capacities are estimates based on drying principles, field results and computer
simulations. Variances may occur due to grain physiological factors (kernel size, chemical composition,
variety, maturity), excessive fines, weather conditions, etc.
140°F
155°F
175°F
Moisture
% Unload
Rate
Dry Time
(Min.)
Capacity
Dry (BPH)
% Unload
Rate
Dry Time
(Min.)
Capacity
Dry (BPH)
% Unload
Rate
Dry Time
(Min.)
Capacity
Dry (BPH)
% In
% Out
15
13
11
33
302
13
28
352
15
24
419
16
13
8
43
228
9
37
266
11
31
316
17
13
7
53
186
8
46
216
9
38
258
18
13
6
63
158
7
54
184
8
45
219
19
13
5
72
137
6
62
160
7
52
190
20
13
4
82
121
5
70
141
6
59
168
21
13
4
92
107
4
79
125
5
66
149
23
13
3
115
86
4
99
100
4
83
119
25
13
2
143
69
3
123
80
3
103
96
120°F
130°F
140°F
Moisture
% Unload
Rate
Dry Time
(Min.)
Capacity
Dry (BPH)
% Unload
Rate
Dry Time
(Min.)
Capacity
Dry (BPH)
% Unload
Rate
Dry Time
(Min.)
Capacity
Dry (BPH)
% In
% Out
15
13
12
29
342
14
25
391
16
22
440
16
13
9
38
258
10
33
295
12
30
332
17
13
7
47
210
9
41
240
10
36
270
18
13
6
55
179
7
48
204
8
43
230
19
13
6
64
155
6
56
178
7
49
200
20
13
5
72
137
6
63
156
6
56
176
21
13
4
81
122
5
71
139
6
63
156
23
13
3
102
97
4
89
111
4
79
125
25
13
3
126
78
3
111
89
4
98
100
Drying table based on 100% unload rate of…...2814 BPH
120°F
140°F
160°F
Moisture
% Unload
Rate
Dry Time
(Min.)
Capacity
Dry (BPH)
% Unload
Rate
Dry Time
(Min.)
Capacity
Dry (BPH)
% Unload
Rate
Dry Time
(Min.)
Capacity
Dry (BPH)
% In
% Out
11
9
10
36
273
12
28
351
15
23
430
12
9
7
48
206
9
37
265
12
30
324
13
9
6
59
168
8
46
216
9
37
264
14
9
5
69
143
7
54
183
8
44
224
15
9
4
80
124
6
62
159
7
51
195
16
9
4
90
109
5
70
141
6
57
172
17
9
3
102
97
4
79
125
5
65
152
18
9
3
114
87
4
89
111
5
73
136
19
9
3
128
77
4
99
100
4
81
122